Mechanics of Bolted Electrical Splices

نویسندگان

  • Samuel Alberts
  • Samuel Thomas Alberts
  • Ilya V. Avdeev
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation on the Effect of Tigthening Torque on the Stress Distribution in Double Lap Simple Bolted and Hybrid (Bolted -Bonded) Joints

In this research, the effects of torque tightening on the stress distribution in double lap simple bolted and hybrid (bolted-bonded) joints have been investigated numerically. In order to determine the bolt clamping force value due to tightening torque in simple bolted and hybrid joints, which is necessary in numerical simulation, an experimental approach has been proposed. To do so, two kinds ...

متن کامل

A review on stress distribution, strength and failure of bolted ‎composite joints

In this study, analytical models considering different material and geometry for ‎both single and double-lap bolted joints were reviewed for better understand how to ‎select the proper model for a particular application. The survey indicades that the ‎analytic models selected for the adhesively single or double bolted lap joints, as well ‎as T, scarf, and stepped joints, with linear material pr...

متن کامل

Evaluation of Fatigue Life Reduction Factors at Bolt Hole in Double Lap Bolted Joints Using Volumetric Method

In this research, the influence of bolt preload on the fatigue strength of 2024-T3 aluminium alloy double lap bolted joints has been studied experimentally and numerically. To do so, three sets of the specimens were prepared and each of them subjected to tightening torque of 1,2.5 and 5 N-m and then fatigue tests were conducted under various cyclic axial load levels. In the numerical method, th...

متن کامل

Nonlinear Modeling of Bolted Lap Jointed Structure with Large Amplitude Vibration of Timoshenko Beams

This paper aims at investigating the nonlinear behavior of a system which is consisting of two free-free beams which are connected by a nonlinear joint. The nonlinear system is modelled as an in-extensional beam with Timoshenko beam theory. In addition, large amplitude vibration assumption is taken into account in order to obtain exact results. The nonlinear assumption in the system necessities...

متن کامل

Bolted moment connections in drive-in and drive-through steel storage racks

Often unbraced, the stability of steel storage racks may depend solely on the pallet beam to upright connector and on the stiffness of the base plate to floor connection ([1]). This paper presents experimental results from cyclic tests performed on portal beam to upright bolted moment connections intended for cold-formed steel drive-in and drive-through storage racks. In storage racks, portal b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016