[Texture of mitral bioprosthesis, ventricular function and formation of thrombus. Analysis through transesophageal echocardiography and use of bioscore].

نویسندگان

  • Henry Abensur
  • Max Grinberg
  • José A F Ramires
چکیده

OBJECTIVE Facing the hypothesis of participation of mechanical stress as a cause of mitral bioprosthesis dysfunction, we decided to assess the relation of preservation of the texture of the mitral bioprosthesis leaflets with left ventricular function, in addition to the casual formation of thrombus in left atrium in patients with left ventricular dysfunction from the implant of mitral bioprosthesis. METHODS Forty 40 patients with mitral bioprosthesis through multiplane transesophageal echocardiogram were studied and divided in two groups: with left ventricular dysfunction (FE=0.40+/-0.09) since the bioprosthesis implant (20 patients: age 47.75+/-11.10 years old and surgery time 5.3+/-2.6 years) and with normal left ventricular function (FE=0.73+/-0.06) since the implant (20 patients: age 49.75+/-13.59 years old and surgery time 5.7+/-3 years). The texture of bioprosthesis leaflets was analyzed through a transesophageal echocardiographic score (FACIMT Bioscore): 1) Fusion of leaflets (score 1 to 3); 2) Apposition of tissues (score 1 to 3); 3) Calcium in leaflets (score 1 to 5); 4) Integrity of leaflets (score 1 to 3); 5) Motility of leaflets (score 1 to 4) and 6) Thickness of leaflets (score 1 to 3). The presence of thrombi in left atrium was assessed through multiplane scanning of the left atrium and left atrial appendage in the transesophageal study. RESULTS There was no significant difference in the texture of bioprosthesis mitral position between the groups, for the total score (8.7+/-2.4 vs. 7.9+/-2.1, p=0.259), and for each analyzed item. A greater incidence of thrombi in left atrium and left atrial appendage was detected in patients with ventricular dysfunction (65% vs. 20%, p=0.004). CONCLUSION The left ventricular dysfunction was not a protecting factor of the texture of bioprosthesis leaflets in mitral position in the tardive post-surgery period. The patients with left ventricular dysfunction showed a more favorable environment for the formation of thrombi in left atrium.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioprosthetic mitral valve thrombosis. Importance of transesophageal echocardiography in the diagnosis and follow-up after treatment.

OBJECTIVE To report the clinical and echocardiographic findings of bioprosthetic mitral valve thrombosis and the value of transesophageal echocardiography (TEE) in its diagnosis and monitoring of thrombolysis. METHODS One hundred and eleven patients with mitral bioprostheses underwent TEE, and 4 out of 7 suspected of having a thrombus on these prostheses were included in the study (mean age =...

متن کامل

Enhanced detection of intracardiac sources of cerebral emboli by transesophageal echocardiography.

We performed transesophageal echocardiography in 50 consecutive hospitalized patients with recent transient ischemic attack or stroke of embolic origin to determine whether transesophageal echocardiography is more sensitive than transthoracic echocardiography in detection of possible intracardiac sources of embolism. Twenty-six of 50 patients with a negative transthoracic echocardiogram for pot...

متن کامل

Blooming Flower in Misty Left Atrium

Left atrial (LA) thrombus is known as a common complication of rheumatic mitral stenosis. It is more common in the presence of atrial fibrillation (AF). Incidence of LA clot formation in sinus rhythm is 2.4–13.5% and the incidence is as high as 33% in patients with mitral stenosis in AF. Because transthoracic echocardiography may not detect the left atrial appendage (LAA) thrombus, transesophag...

متن کامل

Transcatheter transapical valve-in-valve implantation for degenerated mitral bioprosthesis

A 76-year-old woman with a history of aortic and mitral valve (Mosaic 19 mm; Hancock II 25 mm bioprosthesis, Medtronic Inc., Minneapolis, Minnesota) replacement and former coronary artery bypass grafting in 2010 (left internal mammary artery-left anterior descending artery (LIMA-LAD), aorta-obtuse marginal coronary artery (Ao-OM)) was admitted to our hospital with recurrent pulmonary edema. Her...

متن کامل

Evaluation of transesophageal echocardiography in detecting cardiac sources of emboli in ischemic stroke patients

  Background: Embolus is one of the causes of ischemic stroke that can be due to cardiac sources such as valvular heart diseases and atrial fibrillation and atheroma of the aorta. Transesophageal echocardiography (TEE) is superior in identifying potential cardiac sources of emboli. Due to insufficient data on TEE findings in ischemic stroke in Iran, the present study was done to evaluate TEE in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arquivos brasileiros de cardiologia

دوره 84 5  شماره 

صفحات  -

تاریخ انتشار 2005