Stop-flow studies of solute uptake in rat lungs.

نویسندگان

  • R M Effros
  • R Schapira
  • K Presberg
  • K Ozker
  • E R Jacobs
چکیده

Stop-flow studies were used to characterize solute uptake in isolated rat lungs. These lungs were perfused at 8 or 34 ml/min for 10-28 s with solutions containing 125I-albumin and two or more of the following diffusible indicators: [3H]mannitol, [14C]urea, 3HOH, 201Tl+, or 86Rb+. After this loading period, flow was stopped for 10-300 s and then resumed to flush out the perfusate that remained in the pulmonary vasculature during the stop interval. Concentrations of 201Tl+ and 86Rb+ in the venous outflow decreased after the stop interval, indicating uptake from exchange vessels during the stop interval. The amount of these K+ analogs lost from the circulation during the stop interval was greater when the intervals were longer. However, losses of 201T1+ at 90 s approached those at 300 s. Because extraction continued after the vasculature had been flushed, vascular levels had presumably fallen to negligible levels during the stop interval. By 90 s of stop flow the vascular volume that was cleared of 201T1+ averaged 0.657 +/- 0.034 (SE) ml in the experiments perfused at 8 ml/min and 0.629 +/- 0.108 ml in those perfused at 34 ml/min. Increases in perfusate K+ decreased the cleared volumes of 201T1+ and 86Rb+. Uptake of [3H]mannitol, [14C]urea, and 3HOH during the stop intervals was observed only when the lungs were loaded at high flow for short intervals. Decreases in 201T1+ and 86Rb+ concentrations in the pulmonary outflow can be used to identify the fraction of the collected samples that were within exchange vessels of the lung during the stop interval and may help determine the distribution of solute and water exchange along the pulmonary vasculature.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stop-flow studies of distribution of filtration in rat lungs.

The stop-flow approach was used to investigate where filtration occurs in the pulmonary vasculature after elevation of left atrial pressure and aspiration of HCl. Rat lungs were perfused for 11 min at zero left atrial pressures, and then flow was stopped for 10 min and left atrial pressures were increased to 20 cmH2O. Thereafter, 3HOH was instilled into the air spaces, and the pulmonary vascula...

متن کامل

Volumetric and viscometric studies of -alanine in water and ammonia solution at 293- 313K: structure making and breaking effect

The physicochemical properties of solute in solutions provide valuable information on solute –solvent, solute – solute and solvent – solvent interactions. The intermolecular forces between theliquids molecules and solvent molecules affect the viscosity of the solution. Information regardinginter and intra molecular interactions can be obtained from volumetric, and viscometric data in asolute so...

متن کامل

Identifying and Analyzing Stop and Go Traffic based on Asymmetric Theory of Driving Behavior in Acceleration and Deceleration

Stop and go traffic that leads to oscillate traffic flow frequently is observed on congestion flow. Unexpected reasons such as lane – changing maneuvers, lower speeds of leader vehicle and moving bottleneck cause stop and go traffic and amplifying delay and environment impacts. Stop and go traffic exactly can’t be modeled by traffic models, and also car following models based on kinematic flow ...

متن کامل

Fluid reabsorption and glucose consumption in edematous rat lungs.

Solute and water uptake were studied in isolated perfused rat lungs with airspaces filled with the perfusion fluid. The albumin in this solution was labelled with Evans blue (T-1824), and uptake of fluid from the airspaces was documented by an increase in T-1824 concentration in airway fluid of 6.5 +/- 1.6% (n = 5, SEM) at 1 hour and 12.2 +/- 0.9% (n = 10) at 2 hours. The only detectable osmoti...

متن کامل

Effects of acute hyperoxic exposure on solute fluxes across the blood-gas barrier in rat lungs.

We investigated effects of acute hyperoxia on solute transport from air space to vascular space in isolated rat lungs. Air spaces were filled with Krebs-Ringer bicarbonate solution containing fluorescein isothiocyanate-labeled dextran (FD-20; mol wt 20,000) and either 22Na+ and [14C]sucrose, or D-[14C]glucose and L-[3H]glucose. Apparent permeability-surface area products for tracers over time (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 85 3  شماره 

صفحات  -

تاریخ انتشار 1998