Quantitative analysis of posterior capsule opacification of hydrophobic acrylic intraocular lenses.

نویسندگان

  • Hideaki Oharazawa
  • Hisaharu Suzuki
  • Keiko Shibata
  • Yumi Yamada
  • Hironori Matsui
  • Toshihiko Shiwa
  • Hiroshi Takahashi
  • Kunitoshi Ohara
چکیده

Posterior capsule opacification (PCO) remains a common complication of modern cataract surgery, although both modification of materials used and changes in the intraocular lens (IOL) optic edge design have helped to decrease its incidence slightly. Recently, various kinds of quantitative methods have been developed for measuring PCO. The purpose of this study was to compare the quantitative analysis of PCO between different types of IOL designs. Patients enrolled in the study had age-related cataract and underwent uneventful cataract surgery and implantation of either the AcrySof MA30BA (Alcon) or the Sensor AR40e (AMO), which are differently designed hydrophobic acrylic IOLs with a sharp-edged optic design. Postoperative examination was performed at 6 months. Retroillumination photographs of each eye were obtained, and the degree of PCO was assessed using the Evaluation of Posterior Capsule Opacification (EPCO) system. Grade 1 PCO was noted in both the MA30BA and the AR40e groups. There was no significant difference in the mean PCO score between the MA30BA and AR40e groups. Although the sharp-edged optic designs of both IOLs might similarly inhibit PCO at 6 months, a long-term follow-up period is needed to determine if any PCO differences occur between these 2 hydrophobic acrylic IOLs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevention of posterior capsule opacification by an intracapsular open capsule device.

PURPOSE To investigate the ability of an open capsule device to prevent posterior capsule opacification. METHODS A total of 40 eyes of 20 New Zealand white rabbits were randomly divided into six similar groups of 6 to 7 eyes each. After crystalline lens evacuation, one control group (group A) was implanted with a hydrophilic acrylic intraocular lens and no device, and another control group (g...

متن کامل

Neodymium: YAG capsulotomy rates after phacoemulsification with hydrophobic and hydrophilic acrylic intraocular lenses.

PURPOSE To retrospectively evaluate the incidence of neodymium: YAG (ND:YAG) laser capsulotomies for posterior capsule opacification (PCO) seen with hydrophobic and hydrophilic acrylic intraocular lens implants 18 months after surgery. METHODS One hundred and five eyes that had phacoemulsification with a continuous curvilinear capsulorhexis and implantation of either a hydrophobic or a hydrop...

متن کامل

Effect of four different intraocular lenses on posterior capsule opacification.

AIM To evaluate the impact of 4 different intraocular lenses (IOLs) on posterior capsule opacification (PCO) by comparing the neodymium: yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy rates. METHODS This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one cl...

متن کامل

Findings of an experimental study in a rabbit model on posterior capsule opacification after implantation of hydrophobic acrylic and hydrophilic acrylic intraocular lenses

PURPOSE Study on cell growth on the posterior capsule after implantation of hydrophobic acrylic (Acrysof SA 60 AT) and hydrophilic acrylic (Akreos Disc) intraocular lenses (IOL) in a rabbit model and comparison of posterior capsule opacification (PCO). METHODS Phacoemulsification was performed in 22 rabbit eyes, and two different IOL types (Acrysof SA60 AT and Akreos Disc) were implanted. The...

متن کامل

Cost of cataract surgery after implantation of three intraocular lenses

BACKGROUND Posterior capsule opacification is one of the most frequent adverse events following cataract surgery. This manuscript reports the lifetime cost of complications linked to posterior capsule opacification using three types of intraocular lens with square edges. METHODS Costs were estimated from a retrospective study of patients who underwent cataract surgery and data from the litera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of Nippon Medical School = Nippon Ika Daigaku zasshi

دوره 74 1  شماره 

صفحات  -

تاریخ انتشار 2007