New Bayesian discriminator for detection of atrial tachyarrhythmias.

نویسندگان

  • Weichao Xu
  • Hung-Fat Tse
  • Francis H Y Chan
  • Peter Chin Wan Fung
  • Kathy Lai-Fun Lee
  • Chu-Pak Lau
چکیده

BACKGROUND Accurate, rapid detection of atrial tachyarrhythmias has important implications in the use of implantable devices for treatment of cardiac arrhythmia. Currently available detection algorithms for atrial tachyarrhythmias, which use the single-index method, have limited sensitivity and specificity. METHODS AND RESULTS In this study, we evaluated the performance of a new Bayesian discriminator algorithm in the detection of atrial fibrillation (AF), atrial flutter (AFL), and sinus rhythm (SR). Bipolar recording of 364 rhythms (AF=156, AFL=88, SR=120) at the high right atrium were collected from 20 patients who underwent electrophysiological procedures. After initial signal processing, a column vector of 5 features for each rhythm were established, based on the regularity, rate, energy distribution, percent time of quiet interval, and baseline reaching of the rectified autocorrelation coefficient functions. Rhythm identification was obtained by use of Bayes decision rule and assumption of Gaussian distribution. For the new Bayesian discriminator, the overall sensitivity for detection of SR, AF, and AFL was 97%, 97%, and 94%, respectively; and the overall specificity for detection of SR, AF, and AFL was 98%, 98%, and 99%, respectively. The overall accuracy of detection of SR, AF, and AFL was 98%, 97% and 98%, respectively. Furthermore, sensitivity, specificity, and accuracy of this algorithm were not affected by a range of white Gaussian noises with different intensities. CONCLUSIONS This new Bayesian discriminator algorithm, based on Bayes decision of multiple features of atrial electrograms, allows rapid on-line and accurate (98%) detection of AF with robust anti-noise performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevention of inappropriate therapy in implantable cardioverter-defibrillators: results of a prospective, randomized study of tachyarrhythmia detection algorithms.

OBJECTIVES The purpose of this randomized study was to investigate the performance of single- and dual-chamber tachyarrhythmia detection algorithms. BACKGROUND A proposed benefit of dual-chamber implantable cardioverter-defibrillators (ICDs) is improved specificity of tachyarrhythmia detection. METHODS All ICD candidates received a dual-chamber ICD and were randomized to programmed single- ...

متن کامل

A hemodynamically responsive antitachycardia system. Development and basis for design in humans.

Current automatic implantable cardioverter-defibrillators detect tachyarrhythmias primarily by rate-only algorithms and cannot adequately distinguish hemodynamically stable from unstable tachyarrhythmias. The responses of right atrial (mean) and right ventricular pressures (mean, systolic, diastolic, and pulse) to 64 induced and paced supraventricular and ventricular tachyarrhythmias were studi...

متن کامل

Accuracy of mode switch algorithms for detection of atrial tachyarrhythmias.

INTRODUCTION In patients with permanent pacemakers, mode switching events often are interpreted as surrogate markers for atrial tachyarrhythmias. The aim of this study was to determine the accuracy of automatic mode switching algorithms in patients with permanent pacemakers for the diagnosis of atrial tachyarrhythmias. METHODS AND RESULTS Forty patients with tachycardia-bradycardia syndrome a...

متن کامل

Bipolar atrial sensing thresholds in sinus rhythm and atrial tachyarrhythmias. A comparative analysis in patients with DDDR pacemakers.

UNLABELLED Automatic mode switching (AMS) function in dual chamber pacemakers depends on adequate detection of atrial tachyarrhythmias. There are few data on showing how intra-operative atrial signal amplititude during sinus rhythm can predict atrial tachyarrhythmias after pacemaker implantation. In 43 patients undergoing DDDR pacemaker implantation and atrioventricular nodal ablation for the t...

متن کامل

Subclinical atrial fibrillation and the risk of stroke.

BACKGROUND One quarter of strokes are of unknown cause, and subclinical atrial fibrillation may be a common etiologic factor. Pacemakers can detect subclinical episodes of rapid atrial rate, which correlate with electrocardiographically documented atrial fibrillation. We evaluated whether subclinical episodes of rapid atrial rate detected by implanted devices were associated with an increased r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 105 12  شماره 

صفحات  -

تاریخ انتشار 2002