Measurements of orbital volume change using computed tomography in isolated orbital blowout fractures.

نویسندگان

  • Jaehwan Kwon
  • Jose E Barrera
  • Tae-Young Jung
  • Sam P Most
چکیده

OBJECTIVES To measure the orbital volume of unilateral pure blowout fractures with computed tomography before and after surgery and to compare 3-dimensional (3-D) imaging systems. METHODS Twenty-four patients were evaluated with facial computed tomographic scans before and after surgery. Both the orbital volume and the displaced soft tissue volume were measured by 2 operators using 2 different 3-D software programs (Vitrea; Vital Images Inc, Minnetonka, Minnesota; and Dextroscope; Bracco AMT Inc, Princeton, NJ). RESULTS The mean (SD) normal orbital volumes calculated by Vitrea and Dextroscope were 25.5 (2.4) mL and 24.8 (3.0) mL, respectively. The average preoperative orbital volumes were 28.3 (2.3) mL and 27.6 (3.1) mL, while the postoperative volumes were 25.8 (2.5) mL and 24.9 (3.0) mL. Vitrea showed that the average volume of displaced orbital soft tissue was 2.8 (1.9) mL before surgery and that it was reduced to 0.3 (1.3) mL after surgery, while Dextroscope showed that the average displaced orbital soft tissue was 2.9 (1.4) mL before surgery and that it was reduced to 0.1 (1.2) mL after surgery. There was no statistical difference between the 3-D analysis programs. CONCLUSIONS Consistent volume measurements can be obtained using different 3-D image analysis programs. Measuring preoperative and postoperative volume changes and postoperative reduction can ensure a good surgical result and thereby decrease the incidence of enophthalmos.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Orbital volume measurement in the management of pure blowout fractures of the orbital floor.

With the recent advent of accurate orbital volume assessment by computed tomography, a retrospective analysis was made of 31 patients with 'pure' blowout fracture of the orbital floor, managed either surgically or conservatively, to determine whether orbital volume measurement could provide an additional parameter of use in the management of such fractures. There was a significant difference in...

متن کامل

Orbital blowout fractures and race.

PURPOSE To examine the type of orbital blowout fracture and its variation with race. DESIGN Retrospective review of computed tomography (CT) scans and demography in an unselected cohort of patients with orbital blowout fractures. PARTICIPANTS Patients with a high-resolution CT scan of adequate quality for analysis who presented with an orbital blowout fracture to the Orbital Clinic at Moorf...

متن کامل

Prevalence of Diplopia and Extraocular Movement Limitation according to the Location of Isolated Pure Blowout Fractures

BACKGROUND Isolated pure blowout fractures are clinically important because they are the main cause of serious complications such as diplopia and limitation of extraocular movement. Many reports have described the incidence of blowout fractures associated with diplopia and limitation of extraocular movement; however, no studies have statistically analyzed this relationship. The purpose of this ...

متن کامل

A case of blowout fracture of the orbital floor in early childhood

There are few reports of blowout fractures of the orbital floor in children younger than 5 years of age; in a search of the literature, we found only six reported cases which revealed the exact age, correct diagnosis, and treatment. We herein report the case of a 3-year-old boy with a blowout fracture of the orbital floor. Computed tomography showed a pure blowout fracture of the left orbital f...

متن کامل

Use of a Titanium Mesh Plate with High Three-Dimensional Flexibility to Repair an Orbital Floor Fracture: Clinical Note

Orbital blowout fractures are common sequelae of facial trauma. For their treatment, it is now possible to make three-dimensional (3D) implants on the basis of computed tomography (CT) images, using rapid prototyping and to bend the implants preoperatively in the desired shape. However, in orbital fracture, the unique anatomy of the orbit makes the process of fitting and aligning such implants ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of facial plastic surgery

دوره 11 6  شماره 

صفحات  -

تاریخ انتشار 2009