Cardiovascular magnetic resonance feature-tracking assessment of myocardial mechanics: Intervendor agreement and considerations regarding reproducibility

نویسندگان

  • A. Schuster
  • V.-C. Stahnke
  • C. Unterberg-Buchwald
  • J.T. Kowallick
  • P. Lamata
  • M. Steinmetz
  • S. Kutty
  • M. Fasshauer
  • W. Staab
  • J.M. Sohns
  • B. Bigalke
  • C. Ritter
  • G. Hasenfuß
  • P. Beerbaum
  • J. Lotz
چکیده

AIM To assess intervendor agreement of cardiovascular magnetic resonance feature tracking (CMR-FT) and to study the impact of repeated measures on reproducibility. MATERIALS AND METHODS Ten healthy volunteers underwent cine imaging in short-axis orientation at rest and with dobutamine stimulation (10 and 20 μg/kg/min). All images were analysed three times using two types of software (TomTec, Unterschleissheim, Germany and Circle, cvi(42), Calgary, Canada) to assess global left ventricular circumferential (Ecc) and radial (Err) strains and torsion. Differences in intra- and interobserver variability within and between software types were assessed based on single and averaged measurements (two and three repetitions with subsequent averaging of results, respectively) as determined by Bland-Altman analysis, intraclass correlation coefficients (ICC), and coefficient of variation (CoV). RESULTS Myocardial strains and torsion significantly increased on dobutamine stimulation with both types of software (p<0.05). Resting Ecc and torsion as well as Ecc values during dobutamine stimulation were lower measured with Circle (p<0.05). Intra- and interobserver variability between software types was lowest for Ecc (ICC 0.81 [0.63-0.91], 0.87 [0.72-0.94] and CoV 12.47% and 14.3%, respectively) irrespective of the number of analysis repetitions. Err and torsion showed higher variability that markedly improved for torsion with repeated analyses and to a lesser extent for Err. On an intravendor level TomTec showed better reproducibility for Ecc and torsion and Circle for Err. CONCLUSIONS CMR-FT strain and torsion measurements are subject to considerable intervendor variability, which can be reduced using three analysis repetitions. For both vendors, Ecc qualifies as the most robust parameter with the best agreement, albeit lower Ecc values obtained using Circle, and warrants further investigation of incremental clinical merit.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiovascular Magnetic Resonance Myocardial Feature Tracking

Abstract—Heart failure–induced cardiovascular morbidity and mortality constitute a major health problem worldwide and result from diverse pathogeneses, including coronary artery disease, nonischemic cardiomyopathies, and arrhythmias. Assessment of cardiovascular performance is important for early diagnosis and accurate management of patients at risk of heart failure. During the past decade, car...

متن کامل

Quantification of biventricular myocardial function using cardiac magnetic resonance feature tracking, endocardial border delineation and echocardiographic speckle tracking in patients with repaired tetralogy of fallot and healthy controls

BACKGROUND Parameters of myocardial deformation have been suggested to be superior to conventional measures of ventricular function in patients with tetralogy of Fallot (ToF), but have required non-routine, tagged cardiovascular magnetic resonance (CMR) techniques. We assessed biventricular myocardial function using CMR cine-based feature tracking (FT) and compared it to speckle tracking echoca...

متن کامل

Quantitative assessment of myocardial mechanics in patients with cardiac amyloid using cardiovascular magnetic resonance myocardial feature tracking

Background Cardiovascular magnetic resonance (CMR) feature-tracking (FT) allows the quantitative assessment of complex ventricular mechanics such as strain, twist and untwist. LV twist results from the dynamic interplay between systolic clockwise rotation of the base and a counterclockwise rotation of the apex followed by untwisting during diastole. We sought to determine whether strain, myocar...

متن کامل

Quantification of left atrial strain and strain rate using cardiovascular magnetic resonance myocardial feature tracking

Background Cardiovascular Magnetic Resonance myocardial feature tracking (CMR-FT) is a quantitative technique tracking tissue voxel motion on standard steady-state free precession (SSFP) cine images to assess ventricular myocardial deformation. The importance of left atrial (LA) deformation assessment is increasingly recognized and can be assessed with echocardiographic speckle tracking. Howeve...

متن کامل

Global and regional left ventricular myocardial deformation measures by magnetic resonance feature tracking in healthy volunteers: comparison with tagging and relevance of gender

BACKGROUND Feature tracking software offers measurements of myocardial strain, velocities and displacement from cine cardiovascular magnetic resonance (CMR) images. We used it to record deformation parameters in healthy adults and compared values to those obtained by tagging. METHODS We used TomTec 2D Cardiac Performance Analysis software to derive global, regional and segmental myocardial de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 70  شماره 

صفحات  -

تاریخ انتشار 2015