Beckman Access versus the Bayer ACS:180 and the Abbott AxSYM cardiac Troponin-I real-time immunoassays: an observational prospective study
نویسندگان
چکیده
BACKGROUND: Reliability of cardiac troponin-I assays under real-time conditions has not been previously well studied. Most large published cTnI trials have utilized protocols which required the freezing of serum (or plasma) for delayed batch cTnI analysis. We sought to correlate the presence of the acute ischemic coronary syndrome (AICS) to troponin-I values obtained in real-time by three random-mode analyzer immunoassay systems: the Beckman ACCESS (BA), the Bayer ACS:180 (CC) and the Abbott AxSYM (AX). METHODS: This was an observational prospective study at a university tertiary referral center. Serum from a convenience sampling of telemetry patients was analyzed in real-time for troponin-I by either the BA-CC (Arm-1) or BA-AX (Arm-2) assay pairs. Presence of the AICS was determined retrospectively and then correlated with troponin-I results. RESULTS: 100 patients were enrolled in Arm-1 (38 with AICS) and 94 in Arm-2 (48 with AICS). The BA system produced 51% false positives in Arm-1, 44% in Arm-2, with negative predictive values of 92% and 100% respectively. In Arm-1, the BA and the CC assays had sensitivities of 97% and 63% and specificities of 18% and 87%. In Arm-2, the BA and the AX assays had sensitivities of 100% and 83% and specificities of 11% and 78%. CONCLUSIONS: In real-time analysis, the performance of the AxSYM and ACS:180 assay systems produced more accurate troponin-I results than the ACCESS system.
منابع مشابه
Analytical characteristics of commercial cardiac troponin I and T immunoassays in serum from rats, dogs, and monkeys with induced acute myocardial injury.
BACKGROUND Information is needed regarding analytical characteristics of cardiac troponin (cTn) assays used in preclinical studies. METHODS We measured cTnI and cTnT in serum from normal animals and animals with induced myocardial injury [Sprague-Dawley (SD) and Wistar rats, beagle dogs, and rhesus (Rh) and cynomolgus (Cy) monkeys]. We evaluated the following assays: for cTnI, Abbott Architec...
متن کاملMisleading results from immunoassays of serum free thyroxine in the presence of rheumatoid factor.
A novel interference with measurements of serum free thyroxine (FT4) caused by rheumatoid factor (RhF) is described. We found misleading, sometimes gross, increases of FT4 results in 5 clinically euthyroid elderly female patients with high RhF concentrations. All 5 patients had high FT4 on Abbott AxSYM or IMx analyzers. "NETRIA" immunoassays gave misleading results in 4 of the 5 patients; Amerl...
متن کاملNegative interference in cardiac troponin I immunoassays from a frequently occurring serum and plasma component.
BACKGROUND Cardiac troponin I (cTnI) is a sensitive marker of cardiac injury, but cTnI assays, like other immunoassays, are susceptible to interferences. We evaluated the presence of interfering substances by measuring the recovery of cTnI added to samples from volunteers and from patients with acute coronary syndromes (ACS). METHODS We added a ternary complex of human cardiac troponin (30-50...
متن کاملLower cardiac troponin T and I results in heparin-plasma than in serum.
BACKGROUND The use of plasma rather than serum for determination of cardiac troponins can improve turnaround time and potentially avoid incomplete serum separation that may produce falsely increased results. We investigated the influence of incomplete serum separation and the effect of heparin-plasma on cardiac troponin concentrations. METHODS Serum and heparin-plasma samples were drawn simul...
متن کاملUtility of commonly used commercial human chorionic gonadotropin immunoassays in the diagnosis and management of trophoblastic diseases.
BACKGROUND Patients with trophoblastic diseases produce ordinary and irregular forms of human chorionic gonadotropin (hCG; e.g., nicked hCG, hCG missing the beta-subunit C-terminal segment, hyperglycosylated hCG, and free beta subunit) that are recognized to differing extents by automated immunometric hCG (or hCG beta) assays. This has led to low or false-negative results and misdiagnosis of pe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- BMC Emergency Medicine
دوره 4 شماره
صفحات -
تاریخ انتشار 2004