Noninvasive detection of diffuse intracranial disease.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Intracranial arterial stenosis increases flow velocities on the upslope of the Spencer's curve of cerebral hemodynamics. However, the velocity can decrease with long and severely narrowed vessels. We assessed the frequency and accuracy for detection of focal and diffuse intracranial stenoses using novel diagnostic criteria that take into account increased resistance to flow with widespread lesions. METHODS We evaluated consecutive patients referred to a neurovascular ultrasound laboratory with symptoms of cerebral ischemia. Transcranial Doppler mean flow velocities were classified as normal (30 to 99 cm/s), high and low. Pulsatility index >or=1.2 was considered high. Focal intracranial disease was defined as >or=50% diameter reduction by the Warfarin Aspirin in Symptomatic Intracranial Disease criteria. Diffuse disease was defined as stenoses in multiple intracranial arteries, multiple segments of one artery, or a long (>1 cm) stenosis in one major artery on contrast angiography (CT angiography or digital subtraction angiography) as the gold standard. RESULTS One hundred fifty-three patients (96 men, 76% white, age 62+/-15 years) had previous strokes (n=135) or transient ischemic attack (n=18). Transcranial Doppler detection of focal and diffuse intracranial disease had sensitivity 79.4% (95% CI: 65.8% to 93%), specificity 92.4% (95% CI: 87.7% to 97.2%), positive predictive value 75.0% (95% CI: 60.9% to 89.2%), negative predictive value 94.0% (95% CI: 89.7% to 98.3%), and overall accuracy 89.5% (95% CI: 84.5% to 94.4%). After adjustment for stroke risk factors, transcranial Doppler findings of low mean flow velocities and high pulsatility index in a single vessel were independently associated with angiographically demonstrated diffuse single vessel intracranial disease, whereas low mean flow velocities/high pulsatility index in multiple vessels were related to multivessel intracranial disease (OR: 19.7, 95% CI: 4.8 to 81.2, P<0.001). CONCLUSIONS Diffuse intracranial disease may have a higher than expected frequency in a select stroke population and can be detected with noninvasive screening.
منابع مشابه
Noninvasive detection of intracranial vascular lesions by recording blood flow sounds.
BACKGROUND AND PURPOSE Transorbital blood flow sound recordings have the potential to be used for noninvasive detection of cerebral aneurysms and arteriovenous malformations. We describe our system and experience in detecting intracranial cerebrovascular disease. METHODS We investigated the noninvasive detection of intracranial vascular lesions by recording and analyzing the intracranial bloo...
متن کاملMyocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]
Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...
متن کاملDistribution of intracranial vascular lesions in the posterior circulation among Chinese stroke patients
Distribution of atherosclerotic vascular lesions in the intracranial posterior circulation has not been as well documented as in the anterior circulation. Data regarding this aspect among Asian stroke patients are scarce. In present study, we sought to investigate the distribution of posterior circulation vascular lesions in Chinese stroke patients. We examined consecutive patients with acute i...
متن کاملColor velocity imaging quantification in the detection of intracranial collateral flow.
BACKGROUND AND PURPOSE The development of intracranial collateral circulation is associated with a lower risk of stroke. A noninvasive technique that can reliably detect the presence of intracranial collaterals would be a valuable factor in the assessment of risk in patients with occlusive cerebrovascular disease. METHODS Color velocity imaging quantification was used to measure the blood flo...
متن کاملSpontaneous Intracranial Hypotension Plus Cerebral Venous Thrombosis: A Case Report Study
This is a case study of a 34-year-old woman who was admitted to hospital with a history of severe orthostatic headache. She was diagnosed as having spontaneous intracranial hypotension (SIH) by undetectable cerebrospinal fluid (CSF) pressure at lumbar puncture, and with evidence of diffuse dural enhancement of the brain detected by magnetic resonance imaging (MRI). However, the contrast-enhance...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 38 12 شماره
صفحات -
تاریخ انتشار 2007