Evaluation of the Du Pont Axial Separation system.

نویسندگان

  • S L Perkins
  • G A Adams
چکیده

We evaluated the Du Pont Axial Separation Technology (AST) system, which permanently separates a blood specimen into serum or plasma and cells in 1 min. Blood was collected in axial processing containers by standard venipuncture techniques and processed in an Axial Separation Module. Paired patient samples (n = 48 serum pairs, n = 50 plasma pairs) revealed no clinically significant differences in results for common chemistry analytes from samples collected in Becton Dickinson Vacutainer Tubes and centrifuged conventionally vs those from samples collected and processed in the AST system, except for a bias in serum (but not plasma) lactate dehydrogenase activity. This bias was dependent on the extent of stretching of the clot during processing and could be minimized by clotting the blood sample horizontally (axially). We believe the rapid separation of blood by the AST system has the potential to substantially reduce preanalytical specimen handling time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laboratory evaluation of the Du Pont "Dimension Clinical Chemistry System".

We evaluated the analytical performance of the Du Pont Dimension Clinical Chemistry System to assess its suitability as a replacement for the Du Pont aca III, currently routinely used for analysis of pediatric, high-risk, and emergency specimens. Twenty-six analyses were studied. These generally fulfilled pre-set analytical goals for precision based on biological variation or "state of the art....

متن کامل

UV-HPLC / APCI-MS Method for Separation and Identification of the Carotenoids Produced by Sporobolomyces ruberrimus H110

An on-line UV-HPLC / APCI-MS (atmospheric pressure chemical ionization) tandem by a platinium C18 column with an isocratic solvent system after optimizing was applied to the separation and the identification of different carotenoids including astaxanthin, canthaxanthin, apocarotenoic ester, torularhodin and beta carotene. This method was used to identify particular carot...

متن کامل

Evaluation of the revised serum calcium procedure used with the Du Pont automatic clinical analyzer.

We evaluated a revised serum calcium method (o-cresolphthalein complexone) used with the Du Pont aca. Our results correlated well with those obtained by atomic absorption spectrometry. Within-run and day-to-day coefficients of variation were 0.5 and 1.5%, respectively. Color produced and calcium concentration are linearly related and the relation is not affected by hemolysis, lipemia, or icterus.

متن کامل

Mathematical Modelling for Separation of Binary Aqueous Solution using Hollow Fiber Reverse Osmosis Module

The mathematical equation for Separation of the binary aqueous solution is developed by using the SpieglerKedem theory. The characteristics of a B-9 hollow fibre module of Du Pont are determined by using these equations and their results are compared with the experimental results of Ohya et al. The agreement between these results is found to be excellent. Keywords—Binary aqueous solution, model...

متن کامل

Negative interference with the Du Pont aca method for measuring digoxin.

In response to a recent Letter (1) concerning the digoxin method in the aca Discrete Clinical Analyzer, the Dii Pont Company would like to offer the following. As in any enzyme immunoassay, the possibility existsthattheenzyme could be either activated or inhibited by drugs and (or) nonspecific substances, resulting in reported values that do not reflect true concentrations of the drug. We have ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 42 9  شماره 

صفحات  -

تاریخ انتشار 1996