Comparative Study for the Efficacy of Small Bore Catheter in the Patients with Iatrogenic Pneumothorax

نویسندگان

  • Tae Ook Noh
  • Kyoung Min Ryu
چکیده

BACKGROUND It has recently become most general to use the small bore catheter to perform closed thoracostomy in treating iatrogenic pneumothorax. This study was performed for analysis of the efficacy of treatment methods by using small bore catheter such as 7 F (French) central venous catheter, 10 F trocar catheter, 12 F pigtail catheter and for analysis of the appropriateness of each procedure. MATERIALS AND METHODS From March 2007 to February 2010, Retrospective review of 105 patients with iatrogenic pneumothorax, who underwent closed thoracostomy by using small bore catheter, was performed. We analyzed the total success rate for all procedures as well as the individual success rate for each procedure, and analyzed the cause of failure, additional treatment method for failure, influential factors of treatment outcome, and complications. RESULTS The most common causes of iatrogenic pneumothorax were presented as percutaneous needle aspiration(PCNA) in 48 cases (45.7%), and central venous catheterization in 26 cases (24.8%). The mean interval to thoracostomy after the procedure was measured as 5.2 hours (1~34 hours). Total success rate of thoracostomy was 78.1%. The success rate was not significantly difference by tube type, with 7 F central venous catheter as 80%, 10 F trocar catheter as 81.6%, and 12 F pigtail catheter as 71%. Twenty one out of 23 patients that had failed with small bore catheter treatment added large bore conventional thoracostomy, and another 2 patients received surgery. The causes for treatment failure were presented as continuous air leakage in 12 cases (52.2%) and tube malfunction in 7 cases (30%). The causes for failure did not present significant differences by tube type. Statistically significant factors affecting treatment performance were not discovered. CONCLUSION Closed thoracostomy with small bore catheter proved to be effective for iatrogenic pneumothorax. The success rate was not difference for each type. However, it is important to select the appropriate catheter by considering the patient status, pneumothorax aspect, and medical personnel in the cardiothoracic surgery department of the relevant hospital.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of primary and secondary pneumothorax using a small-bore thoracic catheter.

This study aimed to investigate the efficacies and complications associated with the 7F catheter inserted in patients with pneumothorax in the emergency room and to compare the results for primary and secondary pneumothorax. From June 2006 to May 2008, 200 patients with primary or secondary pneumothorax treated with a 7F catheter were enrolled. The primary endpoint was the immediate success rat...

متن کامل

Effectiveness of Ambulatory Tru-Close Thoracic Vent for the Outpatient Management of Pneumothorax: A Prospective Pilot Study

OBJECTIVE This study aimed to assess the technical feasibility, procedural safety, and long-term therapeutic efficacy of a small-sized ambulatory thoracic vent (TV) device for the treatment of pneumothorax. MATERIALS AND METHODS From November 2012 to July 2013, 18 consecutive patients (3 females, 15 males) aged 16-64 years (mean: 34.7 ± 14.9 years, median: 29 years) were enrolled prospectivel...

متن کامل

Outpatient Treatment for Pneumothorax Using a Portable Small-Bore Chest Tube: A Clinical Report

BACKGROUND For treatment of pneumothorax in Korea, many institutions hospitalize the patient after chest tube insertion. In this study, a portable small-bore chest tube (Thoracic Egg; Sumitomo Bakelite Co. Ltd., Tokyo, Japan) was used for pneumothorax management in an outpatient clinic. METHODS Between August 2014 and March 2015, 56 pneumothorax patients were treated using the Thoracic Egg. ...

متن کامل

Role of small calibre chest tube drainage for iatrogenic pneumothorax.

A 2 mm Teflon catheter was used as a chest tube in 28 patients with iatrogenic pneumothorax. Frequent aspirations through the catheter were performed in 16 of the patients. In the remaining 12 patients the catheter was connected to a one way flutter valve. The treatment was successful in 27 of the 28 patients--one patient required a large calibre chest tube. The mean drainage time was 48 hours....

متن کامل

Preventing Traumatic Urinary Catheter Insertion Through a Computerized Ordering System: Quasi-experimental Study From a Tertiary Academic Center

Background: Iatrogenic urethral injury is a well-known risk of urinary catheter insertion. Associated morbidities include stricture formation, catheter associated infection, risk for instrumentation, and extended length of stay. Yet, insufficient attention is paid to its prevention. Objective: This study aimed to assess the effectiveness of a computerized...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 44  شماره 

صفحات  -

تاریخ انتشار 2011