4D MAP Image Reconstruction Incorporating Organ Motion
نویسندگان
چکیده
Four-dimensional respiratory correlated computed tomography (4D RCCT) has been widely used for studying organ motion. Most current algorithms use binning techniques which introduce artifacts that can seriously hamper quantitative motion analysis. In this paper, we develop an algorithm for tracking organ motion which uses raw time-stamped data and simultaneously reconstructs images and estimates deformations in anatomy. This results in a reduction of artifacts and an increase in signal-to-noise ratio (SNR). In the case of CT, the increased SNR enables a reduction in dose to the patient during scanning. This framework also facilitates the incorporation of fundamental physical properties of organ motion, such as the conservation of local tissue volume. We show in this paper that this approach is accurate and robust against noise and irregular breathing for tracking organ motion. A detailed phantom study is presented, demonstrating accuracy and robustness of the algorithm. An example of applying this algorithm to real patient image data is also presented, demonstrating the utility of the algorithm in reducing artifacts.
منابع مشابه
Simultaneous acquisition of image and navigator slices using CAIPIRINHA for 4D MRI.
PURPOSE Respiratory organ motion is still the major challenge of various image-guided treatments in the abdomen. Dynamic organ motion tracking, necessary for the treatment control, can be performed with volumetric time-resolved MRI that sequentially acquires one image and one navigator slice. Here, a novel imaging method is proposed for truly simultaneous high temporal resolution acquisition. ...
متن کاملAward Number : DAMD 17 - 03 - 1 - 0657 TITLE : Multiple Aperture Radiation Therapy ( MART ) for Breast Cancer
On-board imager (OBI) based cone-beam computed tomography (CBCT) has become available in radiotherapy clinics to accurately identify the target in the treatment position. However, due to the relatively slow gantry rotation (typically about 60 s for a full 360◦ scan) in acquiring the CBCT projection data, the patient’s respiratory motion causes serious problems such as blurring, doubling, streak...
متن کامل4D CT image reconstruction with diffeomorphic motion model
Four-dimensional (4D) respiratory correlated computed tomography (RCCT) has been widely used for studying organ motion. Most current RCCT imaging algorithms use binning techniques that are susceptible to artifacts and challenge the quantitative analysis of organ motion. In this paper, we develop an algorithm for analyzing organ motion which uses the raw, time-stamped imaging data to reconstruct...
متن کاملAn optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing.
Respiratory motion degrades anatomic position reproducibility and leads to issues affecting image acquisition, treatment planning, and radiation delivery. Four-dimensional (4D) computer tomography (CT) image acquisition can be used to measure the impact of organ motion and to explicitly account for respiratory motion during treatment planning and radiation delivery. Modern CT scanners can only ...
متن کاملFour-Dimensional Image Reconstruction Strategies in Cardiac-Gated and Respiratory-Gated PET Imaging.
Cardiac and respiratory movements pose significant challenges to image quality and quantitative accuracy in PET imaging. Cardiac and/or respiratory gating attempt to address this issue, but instead lead to enhanced noise levels. Direct four-dimensional (4D) PET image reconstruction incorporating motion compensation has the potential to minimize noise amplification while removing considerable mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Information processing in medical imaging : proceedings of the ... conference
دوره 21 شماره
صفحات -
تاریخ انتشار 2009