Torso stabilization reduces the metabolic cost of producing cycling power.
نویسندگان
چکیده
Many researchers have used cycling exercise to evaluate muscle metabolism. Inherent in such studies is an assumption that changes in whole-body respiration are due solely to respiration at the working muscle. Some researchers, however, have speculated that the metabolic cost of torso stabilization may contribute to the metabolic cost of cycling. Therefore, our primary purpose was to determine whether a torso stabilization device would reduce the metabolic cost of producing cycling power. Our secondary purpose was to determine the validity of the ergometer used in this study. Nine male cyclists cycled on a Velotron cycle ergometer at mechanical power outputs intended to elicit 50, 75, and 100% of their ventilatory threshold at 40, 60, and 80 rpm, with and without torso stabilization. Power was controlled by the Velotron in iso-power mode and measured with an SRM powermeter. We determined metabolic cost by indirect calorimetery and recorded power output. Torso stabilization significantly reduced metabolic cost of producing submaximal power (1%), and reduction tended to be greatest at the lower pedaling rates where pedaling force was greatest (1.6% at 40 rpm, 1.2% at 60 rpm, 0.2% at 80 rpm). Power, measured with the SRM powermeter, was strongly correlated with that specified to the Velotron ergometer control unit (R(2) > 0.99). We conclude that muscular contractions associated with torso stabilization elicit significant metabolic costs, which tend to be greatest at low pedaling rates. Researchers who intend to make precise inferences regarding metabolism in the working muscles of the legs may wish to provide torso stabilization as a means of reducing variability, particularly when comparing metabolic data across a wide range of pedaling rates.
منابع مشابه
Determinants of metabolic cost during submaximal cycling.
The metabolic cost of producing submaximal cycling power has been reported to vary with pedaling rate. Pedaling rate, however, governs two physiological phenomena known to influence metabolic cost and efficiency: muscle shortening velocity and the frequency of muscle activation and relaxation. The purpose of this investigation was to determine the relative influence of those two phenomena on me...
متن کاملCost Efficiency Evaluation via Data Envelopment Analysis Approach for Undesirable Outputs based on the Weak Disposability Axiom (Case Study: 56 Electricity Producing Thermal Power Plants in Iran)
Cost efficiency evaluation is a very important and applicable issue in Data Envelopment Analysis (DEA). In this paper, the classical cost efficiency model in which all the input prices are known and fixed for each decision making unit is developed via undesirable outputs with the weak disposability axiom. The proposed model is a nonlinear model under the variable returns to scale condition,...
متن کاملThe metabolic cost of human running: is swinging the arms worth it?
Although the mechanical function is quite clear, there is no consensus regarding the metabolic benefit of arm swing during human running. We compared the metabolic cost of running using normal arm swing with the metabolic cost of running while restricting the arms in three different ways: (1) holding the hands with the arms behind the back in a relaxed position (BACK), (2) holding the arms acro...
متن کاملOn the energetics of quadrupedal running: predicting the metabolic cost of transport via a flexible-torso model.
In this paper, the effect of torso flexibility on the energetics of quadrupedal bounding is examined in a template setting. Two reductive sagittal-plane models, one with a rigid, non-deformable torso and one with a flexible, unactuated torso are proposed. Both models feature non-trivial leg mass and inertia to capture the energy associated with repositioning the legs after liftoff as well as th...
متن کاملDo Vascular Networks Branch Optimally or Randomly across Spatial Scales?
Modern models that derive allometric relationships between metabolic rate and body mass are based on the architectural design of the cardiovascular system and presume sibling vessels are symmetric in terms of radius, length, flow rate, and pressure. Here, we study the cardiovascular structure of the human head and torso and of a mouse lung based on three-dimensional images processed via our sof...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Canadian journal of applied physiology = Revue canadienne de physiologie appliquee
دوره 30 4 شماره
صفحات -
تاریخ انتشار 2005