Transcranial Doppler detection of microemboli during percutaneous transluminal coronary angioplasty.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The use of percutaneous transluminal coronary angioplasty (PTCA) to treat coronary artery disease is now commonplace. The occurrence of microemboli during invasive procedures such as cardiac angiography and bypass surgery is well documented, although neurological complications are relatively uncommon. To date, no investigation has been undertaken of the frequency or nature of microemboli occurring during PTCA or of the correlation with aortic atheroma. METHODS Twenty patients having elective PTCA underwent examination by transcranial Doppler ultrasonography (TCD) to detect left middle cerebral artery microemboli occurring during the procedure. Blinded off-line analysis correlated microembolic signal counts on TCD with the components of each stage of the PTCA. Patients later underwent transesophageal (TEE) echocardiography, with measurements made of the thickness of the intima and atheroma in the ascending and descending thoracic aortic arch by cardiologists blinded to the TCD results. RESULTS A total of 973 microembolic signals were detected (mean+/-SD, 48.7+/-36.7 per patient); 196 (20%) occurred on movement of the PTCA catheter and wire around the aortic arch, 84 (9%) with other PTCA catheter-associated movements, and 679 (70%) in association with injection of solutions (eg, saline and contrast). Mean signal counts during contrast injection were significantly greater than during the other 3 phases (P<0.001). No neurological events occurred in the study. Although not statistically significant, there was a trend toward greater microembolic signal counts with the number of times the catheter was passed around the aortic arch and the amount of arch atheroma detected by transesophageal echocardiography. CONCLUSIONS Microemboli detected on TCD are a common occurrence during PTCA but are largely asymptomatic. The majority of microembolic signals are most probably gaseous in origin and do not appear to be related to the extent of aortic atheroma or to clinical events.
منابع مشابه
Comparison of microembolism detected by transcranial Doppler and neuropsychological sequelae of carotid surgery and percutaneous transluminal angioplasty.
BACKGROUND AND PURPOSE Percutaneous transluminal angioplasty (PTA) is currently being assessed for the treatment of carotid stenosis. In comparison with carotid endarterectomy (CEA), there is evidence of an increased risk of cerebral microembolism during the procedure. We have sought evidence of any neuropsychological sequelae of carotid PTA and compared it with CEA to demonstrate the relative ...
متن کاملClinical significance of microembolus detection by transcranial Doppler sonography in cardiovascular clinical conditions.
Transcranial Doppler can detect microembolic signals, which are characterized by unidirectional high intensity increase, short duration, and random occurrence, producing a "whistling" sound. Microembolic signals have been proven to represent solid or gaseous particles within the blood flow. Microemboli have been detected in a number of clinical cardiovascular settings: carotid artery stenosis, ...
متن کاملThe value of myocardial perfusion imaging with Tc-99m MIBI for the prediction of perfusion improvement after percutaneous transluminal coronary angioplasty
Introduction: Percutaneous transluminal coronary angioplasty (PTCA) is an effective method for revascularizing of stenotic coronary vessels. Lack of response to this treatment, either in symptomatic or asymptomatic patients, is usually due to incomplete revascularization, restenosis, and/or irreversibility of myocardial perfusion. Introduction of a noninvasive metho...
متن کاملAssessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)
Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...
متن کاملCoronary blood flow velocity during percutaneous transluminal coronary angioplasty as a guide for assessment of the functional result.
To investigate the clinical usefulness of intracoronary Doppler recordings during percutaneous transluminal coronary angioplasty (PTCA), the changes of intracoronary blood flow velocity during PTCA were assessed in 20 patients with single proximal coronary stenosis, using a Doppler probe end-mounted on the tip of a PTCA catheter. A mean of 4 inflations was performed in each patient. Intracorona...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 29 11 شماره
صفحات -
تاریخ انتشار 1998