Diffusion-controlled detection of glucose with microelectrodes in mediated bioelectrocatalytic oxidation.

نویسندگان

  • Tatsuo Noda
  • Mizue Wanibuchi
  • Yuki Kitazumi
  • Seiya Tsujimura
  • Osamu Shirai
  • Masahiro Yamamoto
  • Kenji Kano
چکیده

This paper describes a diffusion-controlled electrolysis of glucose with mediated bioelectrocatalysis at microdisk-electrodes. Under conditions of an extremely fast enzyme reaction, compared with the diffusion of glucose, the current in potential-step chronoamperometry reaches an almost steady state within 10 s, and is proportional to the glucose concentration. The current can be detected at +0.1 V (vs. Ag|AgCl) with 9,10-phenanthrenequinone as a mediator. The addition of carboxymethylcellulose increased the linear range up to 10 mM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioelectrocatalytic oxidation of glucose with antibiotic channel-containing liposomes.

We developed an efficient bioelectrocatalytic system for glucose oxidation by introducing hydrophilic glucose-permeable antibiotic channels into liposomes.

متن کامل

Diffusion-controlled Mediated Electron Transfer-type Bioelectrocatalysis Using Microband Electrodes as Ultimate Amperometric Glucose Sensors.

We performed numerical simulations on an extremely fast, mediated, electron transfer-type bioelectrocatalytic reaction using a microband electrode. The simulations under fast-enzyme-kinetics conditions predicted that the decrement of the current density by increaseing the microband thickness would effectively improve the upper limit of detection. These predictions were accurate for an ultrathin...

متن کامل

Characteristics of fast mediated bioelectrocatalytic reaction near microelectrodes.

The pseudo-steady-state current due to a mediated enzymatic reaction on a microelectrode is characterized on the basis of theoretical analysis and numerical simulation. The steady-state current is proportional to substrate concentration when the enzymatic reaction is considerably faster than substrate mass transport via nonlinear diffusion. Under such conditions, the reaction plane, where the m...

متن کامل

Kinetic Studies of the Catalytic Oxidation of Toluene to Benzoic Acid in the Liquid Phase

The catalytic oxidation of toluene to benzoic acid in the liquid phase has been studied in an un-stirred tank reactor. Low concentration of acetic acid was added in order to increase the solubility of the catalyst in toluene. The dependence of the rate of reaction on the concentration of toluene catalyst and oxygen pressure was studied. It has been suggested that liquid phase oxidation of t...

متن کامل

Scanning electrochemical microscopy. 24. Enzyme ultramicroelectrodes for the measurement of hydrogen peroxide at surfaces.

Hydrogen peroxide sensing microelectrodes for scanning electrochemical microscopy (SECM) have been developed and used to measure hydrogen peroxide in the diffusion layer during electrochemical reduction of oxygen on gold and carbon electrodes. These microelectrode biosensors were also used to detect immobilized glucose oxidase through the production of hydrogen peroxide during enzymatic oxidati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 29 3  شماره 

صفحات  -

تاریخ انتشار 2013