Thrombogenic potential of Innovia polymer valves versus Carpentier-Edwards Perimount Magna aortic bioprosthetic valves.

نویسندگان

  • Thomas E Claiborne
  • Gaurav Girdhar
  • Siobhain Gallocher-Lowe
  • Jawaad Sheriff
  • Yasushi P Kato
  • Leonard Pinchuk
  • Richard T Schoephoerster
  • Jolyon Jesty
  • Danny Bluestein
چکیده

Trileaflet polymeric prosthetic aortic valves (AVs) produce hemodynamic characteristics akin to the natural AV and may be most suitable for applications such as transcatheter implantation and mechanical circulatory support (MCS) devices. Their success has not yet been realized due to problems of calcification, durability, and thrombosis. We address the latter by comparing the platelet activation rates (PARs) of an improved polymer valve design (Innovia LLC) made from poly(styrene-block-isobutylene-block-styrene) (SIBS) with the commercially available Carpentier-Edwards Perimount Magna Aortic Bioprosthetic Valve. We used our modified prothrombinase platelet activity state (PAS) assay and flow cytometry methods to measure platelet activation of a pair of 19 mm valves mounted inside a pulsatile Berlin left ventricular assist device (LVAD). The PAR of the polymer valve measured with the PAS assay was fivefold lower than that of the tissue valve (p = 0.005) and fourfold lower with flow cytometry measurements (p = 0.007). In vitro hydrodynamic tests showed clinically similar performance of the Innovia and Magna valves. These results demonstrate a significant improvement in thrombogenic performance of the polymer valve compared with our previous study of the former valve design and encourage further development of SIBS for use in heart valve prostheses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

BACKGROUND Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. METHODS AND RESULTS We report data from 20 consecutive clinical cases in which BVF was successfully performed before or afte...

متن کامل

Comparative hydrodynamic evaluation of bioprosthetic heart valves.

BACKGROUND AND AIM OF STUDY Pressure gradients across cardiac valve prostheses have been identified as one of the most important performance measures in valve replacement surgery. Specifically in aortic valves, these gradients influence reduction of left ventricular hypertrophy and are postulated to influence long-term survival. The correct choice of replacement valve is hampered by a lack of u...

متن کامل

eComment. The current bioprosthesis of choice for aortic valve replacements.

ference in postoperative aortic valve area, maximum velocity across the valve and mortality. Pelletier et al. [8] performed a cohort study comparing 878 CE porcine and 715 Ionescu-Shiley, CE and Mitroflow bovine valves in AVR, MVR or MR from 1976–88. It showed similar late survival rates and clinical improvement. However, the freedom from all valve-related complications was significantly better...

متن کامل

The Fluid Dynamical Performance of the Carpentier-Edwards PERIMOUNT Magna Ease Prosthesis

The aim of the present in vitro study was the evaluation of the fluid dynamical performance of the Carpentier-Edwards PERIMOUNT Magna Ease depending on the prosthetic size (21, 23, and 25 mm) and the cardiac output (3.6-6.4 L/min). A self-constructed flow channel in combination with particle image velocimetry (PIV) enabled precise results with high reproducibility, focus on maximal and local pe...

متن کامل

Stentless aortic valve replacement: an update

Although porcine aortic valves or pericardial tissue mounted on a stent have made implantation techniques easier, these valves sacrifice orifice area and increase stress at the attachment of the stent, which causes primary tissue failure. Optimizing hemodynamics to prevent patient-prosthetic mismatch and improve durability, stentless bioprostheses use was revived in the early 1990s. The purpose...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • ASAIO journal

دوره 57 1  شماره 

صفحات  -

تاریخ انتشار 2011