Patient-ventilator interaction and inspiratory effort during pressure support ventilation in patients with different pathologies.

نویسندگان

  • S Nava
  • C Bruschi
  • C Fracchia
  • A Braschi
  • F Rubini
چکیده

The aim of this study was to evaluate whether pressure support ventilation (PSV) requires different diaphragmatic efforts and patient-ventilator matching, according to the underlying disease. Four groups of patients requiring PSV were studied: Group A, recovering from an episode of acute respiratory failure due to adult respiratory distress syndrome (ARDS); Group B, with postsurgical complications; and two subsets of chronic obstructive pulmonary disease (COPD) patients, with "normal" static compliance of the respiratory system (Cst,rs) (Group C) or elevated Cst,rs (Group D). Ventilatory pattern, transdiaphragmatic pressure (Pdi), the pressure-time product of the diaphragm (PTPdi), static (PEEPi,stat) and dynamic intrinsic positive end-expiratory pressure (PEEPi,dyn), Cst,rs and resistance of the total respiratory system (Rrs) were recorded. The matching between patient and ventilator was analysed, recording the number of "ineffective efforts" (inspiratory efforts not efficient enough to trigger a new ventilator cycle, despite a positive deflection in Pdi). A satisfactory blood gas equilibrium arterial oxygen saturation (Sa,O2 > 93%, with a pH > 7.32) was obtained in the various groups with different levels of PSV. Minute ventilation was found to be significantly higher in Groups A and B, due to the longer expiratory time (tE) in the COPD groups. Group A (2 out of 7), Group B (3 out of 7), Group C (3 out of 5) patients showed sporadic "ineffective efforts". All Group D patients manifested continuous mismatching with the ventilator, so that the pressure-time product of the diaphragm per minute (PTPdi/min), reflecting the metabolic work of the diaphragm, was not different in the four groups. Tidal volume and the spontaneous inspiratory efforts were similar in the four groups, but the number of breaths delivered by the ventilator was significantly higher in Groups A and B. The application of different levels of pressure support ventilation in patients with acute respiratory failure due to different pathologies, led them to breathe with comparable pressure time product of the diaphragm. The majority of the patients showed mismatching with the ventilator, although this effect was more pronounced in the groups with chronic obstructive pulmonary disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of mask and helmet interfaces to deliver noninvasive ventilation in a human model of resistive breathing.

The helmet, a transparent latex-free polyvinyl chloride cylinder linked by a metallic ring to a soft collar that seals the helmet around the neck, has been recently proposed as an effective alternative to conventional face mask to deliver pressure support ventilation (PSV) during noninvasive ventilation in patients with acute respiratory failure. We tested the hypothesis that mechanical charact...

متن کامل

A diaphragmatic electrical activity-based optimization strategy during pressure support ventilation improves synchronization but does not impact work of breathing

BACKGROUND Poor patient-ventilator synchronization is often observed during pressure support ventilation (PSV) and has been associated with prolonged duration of mechanical ventilation and poor outcome. Diaphragmatic electrical activity (Eadi) recorded using specialized nasogastric tubes is a surrogate of respiratory brain stem output. This study aimed at testing whether adapting ventilator set...

متن کامل

A bench study of 2 ventilator circuits during helmet noninvasive ventilation.

OBJECTIVE To compare helmet noninvasive ventilation (NIV), in terms of patient-ventilator interaction and performance, using 2 different circuits for connection: a double tube circuit (with one inspiratory and one expiratory line) and a standard circuit (a Y-piece connected only to one side of the helmet, closing the other side). METHODS A manikin, connected to a test lung set at 2 breathing ...

متن کامل

Patient-Ventilator Interaction During Noninvasive Ventilation in Simulated COPD.

BACKGROUND During noninvasive ventilation (NIV) of COPD patients, delayed off-cycling of pressure support can cause patient ventilator mismatch and NIV failure. This systematic experimental study analyzes the effects of varying cycling criteria on patient-ventilator interaction. METHODS A lung simulator with COPD settings was connected to an ICU ventilator via helmet or face mask. Cycling was...

متن کامل

Different modes of assisted ventilation in patients with acute respiratory failure.

The aim of the present study was to verify that the patient/ventilator interaction is similar, regardless of the mode of assisted mechanical ventilation (i.e. pressure- or volume-limited) used, if tidal volume (VT) and peak inspiratory flow (PIF) are matched. Therefore, the authors compared the effects of three different modes of assisted ventilation on the work of breathing (WOB) and gas excha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 1997