A novel intracavitary applicator design for the treatment of deep vaginal fornices: preliminary dose metrics and geometric analysis

نویسندگان

  • Antonio L. Damato
  • Robert A. Cormack
  • Akila N. Viswanathan
چکیده

PURPOSE To investigate the dose distributions associated with a novel balloon sleeve placed over a standard cylinder applicator. MATERIAL AND METHODS A computed tomography (CT) scan of a sleeve balloon shaped to inflate into the vaginal fornices was used to digitize 1-, 3-, and 5-catheter configurations. Point doses for rectum, apex, and fornix were calculated and compared to the values associated with a standard cylinder plan not targeting the vaginal fornices. Inflation of the sleeve balloon in the vaginal fornices and dose coverage with constraints to the rectum, bladder, and sigmoid D2cc were evaluated. RESULTS Rectum, apex, and fornix doses were respectively 76%, 119%, and 44% for a standard cylinder; 190%, 310%, and 93% for a 1-catheter configuration; 98%, 109%, and 109% for a 3-catheter configuration; and 91%, 107%, and 96% for the 5-catheter configuration. In a patient analysis, expansion of the sleeve balloon into the vaginal fornices was confirmed. The 5-catheter configurations were associated with best coverage of the fornices and acceptable doses to rectum, bladder, and sigmoid. CONCLUSIONS A 1-catheter configuration cannot be used clinically due to high rectal and apex dose. In theoretical analysis, the 3- and 5-catheter configurations showed > 96% coverage to the vaginal fornices with a clinically acceptable rectal dose. In a treatment simulation in a patient, a 5-catheter configuration showed 90% coverage of the fornices with acceptable doses to the organs at risk. The treatment of deep vaginal fornices results in an increased rectal dose compared to a standard cylinder plan.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rectal wall dose estimation in intracavitary brachytherapy: A preliminary comparison of an in-house rectal wire versus ICRU 38 recommendations

Background: In intracavitary brachytherapy for gynecological cancers, various techniques are used to locate the anterior rectal wall nearest to the sources but there is no consensus on the best method to do so. This study aimed to compare a technique used routinely in some centers that employs a wire marker to locate the position of the maximum rectal dose point, versus the method recommended b...

متن کامل

Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning

PURPOSE To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff ...

متن کامل

Intracavitary vaginal brachytherapy using a custom balloon applicator

A custom balloon applicator was created to deliver intracavitary high-dose-rate brachytherapy to a patient with a superficial vaginal cancer. The patient was unable to be treated conventionally due to an extremely narrow introitus that prevented the introduction of a conventional cylinder applicator. The custom applicator was constructed by inserting a straight titanium tandem applicator throug...

متن کامل

Study of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis

Background: This study evaluates dosimetric and spatial variations in inter–fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...

متن کامل

Dosimetric evaluation of a newly designed low dose rate brachytherapy applicator for treatment of cervical cancer with extension into the lower vagina

Currently, patients having cervical cancer with extension into the lower vagina are being treated with a combination of the Fletcher-Suit applicator, which treats the cervix, and a vaginal cylinder, which treats the lower vagina. With this method, patients receive two separate implants-a procedure that creates greater uncertainty in the dose distribution and unnecessary patient inconvenience. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 