Single-input double-tuned birdcage coil with identical B1 field profile for 1H and 19F imaging

نویسندگان

  • L. Hu
  • F. D. Hockett
  • J. Chen
  • G. M. Lanza
  • S. A. Wickline
چکیده

Introduction: A double tuned birdcage coil was widely studied for its good field homogeneity and convenience in support of a heteronuclear MRI experiment. Since the birdcage coil is a multi-mode resonator with complicated electrical property, its double-tuned version is often designed to achieve the required frequency shift by geometrically rearranging coil legs, adding new tunable elements to specific legs, or varying shield size [1-3]. We proposed a novel design of double-tuned birdcage coil by inserting a secondary resonator in the feeding circuit without changing the structure of birdcage coil. The frequency response and magnetic field distribution of the coil were measured followed by in vivo demonstration. Furthermore, we experimentally showed that our coil is able to be integrated with active decoupling technique [4].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of Crisscrossed Double-Layer Birdcage Coil for Improving B1 + Field Homogeneity for Small-Animal Magnetic Resonance Imaging at 300 MHz

We design a crisscrossed double-layer birdcage (DLBC) coil by modifying the coil geometry of a standard single-layer BC (SLBC) coil to enhance the homogeneity of transmitting magnetic flux density (B1 ) along the main magnetic field (B0)-direction for small-animal magnetic resonance imaging (MRI) at 300 MHz. The performance assessment of the crisscrossed DLBC coil is conducted by computational ...

متن کامل

Simultaneous 23Na/1H Imaging with Dual Excitation and Double Tuned Birdcage Coil

Introduction The tissue concentration of sodium is sensitive to disease as an indicator of cellular and metabolic integrity [1]. Due to the low 23Na MR signal level, however, relatively long scan times are required. Furthermore, an additional 1H image in needed for an anatomic co-registration. In this context, a truly simultaneous acquisition of the 23Na and 1H signal would be helpful to reduce...

متن کامل

SAR and B1 Field in a Human Head Model for Birdcage, TEM and Microstrip Coils at 7T

Introduction: The advantage of high field MRI is high SNR which can increase image resolution or decrease acquisition time. However, there are some challenges, such as the RF wavelength effect and the power deposition in tissues. A comparison of three different volume coils loaded with the same spherical homogeneous phantom has been reported [1]. In order to mimic the B1 field distribution and ...

متن کامل

A High-pass Birdcage Coil for Small Animal Imaging at 600MHz/14.1T

Introduction: Birdcage coils become difficult to build at high field strength, as smaller capacitor values are required and coil sections become large relative to the RF wavelength. This abstract demonstrates a birdcage coil operating at 600MHz (λfree space=0.5m) for small animal imaging. Methods: A 12-rung high-pass design was chosen (50mm diameter × 32mm long, 2mm track width; 120mm diameter ...

متن کامل

Double Tuned 31P/1H Elliptical Transceiver Phased Array for the Human Brain Studies at 7 T

Introduction: The improved SNR at 7T provides significant advantages for both H and lower gyromagnetic nuclei such as P, Na and C (X nuclei). Double resonant volume head coils, based on both birdcage (1-3) and TEM (4) designs have been previously used at lower magnetic fields. However at 7T, transceiver phased arrays provide significant advantages for both B1 homogeneity and transmit efficiency...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009