Electropathological Substrate of Long-Standing Persistent Atrial Fibrillation in Patients With Structural Heart Disease

نویسندگان

  • Maurits A. Allessie
  • Richard P.M. Houben
  • Joep L. Smeets
  • Harry J. Crijns
چکیده

Background—The electropathological substrate of persistent atrial fibrillation (AF) in humans is largely unknown. The aim of this study was to compare the spatiotemporal characteristics of the fibrillatory process in patients with normal sinus rhythm and long-standing persistent AF. Methods and Results—During cardiac surgery, epicardial mapping (244 electrodes) of the right atrium (RA), the left lateral wall (LA), and the posterior left atrium (PV) was performed in 24 patients with long-standing persistent AF. Twenty-five patients with normal sinus rhythm, in whom AF was induced by rapid pacing, served as a reference group. A mapping algorithm was developed that separated the complex fibrillation process into its individual elements (wave mapping). Parameters used to characterize the substrate of AF were (1) the total length of interwave conduction block, (2) the number of fibrillation waves, and (3) the ratio of block to collision of fibrillation waves (dissociation index). In 4403 maps of persistent AF, no evidence for the presence of stable foci or rotors was found. Instead, many narrow wavelets propagated simultaneously through the atrial wall. The lateral boundaries of these waves were formed by lines of interwave conduction block, predominantly oriented parallel to the atrial musculature. Lines of block were not fixed but continuously changed on a beat-to-beat basis. In patients with persistent AF, the total length of block in the RA was more than 6-fold higher than during acute AF (median, 21.1 versus 3.4 mm/cm; P 0.0001). The highest degree of interwave conduction block was found in the PV area (33.0 mm/cm). The number of fibrillation waves during persistent AF was 4.5/cm compared with 2.3 during acute AF, and the dissociation index was 7.3 versus 1.5 (P 0.0001). The interindividual variation of these parameters among patients was high. Conclusions—Electric dissociation of neighboring atrial muscle bundles is a key element in the development of the substrate of human AF. The degree of the pathological changes can be measured on an individual basis by electrophysiological parameters in the spatial domain. (Circ Arrhythm Electrophysiol. 2010;3:606-615.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electropathological substrate of long-standing persistent atrial fibrillation in patients with structural heart disease: longitudinal dissociation.

BACKGROUND The electropathological substrate of persistent atrial fibrillation (AF) in humans is largely unknown. The aim of this study was to compare the spatiotemporal characteristics of the fibrillatory process in patients with normal sinus rhythm and long-standing persistent AF. METHODS AND RESULTS During cardiac surgery, epicardial mapping (244 electrodes) of the right atrium (RA), the l...

متن کامل

Human atrial fibrillation substrate: towards a specific fibrotic atrial cardiomyopathy.

The atrial structure/substrate of patients with atrial fibrillation (AF) and clinically similar characteristics can present very differently, and also the 'phenotype' (i.e. paroxysmal, persistent, and long standing persistent) of the arrhythmia cannot comprehensively explain these differences. It was unclear why some patients stay in paroxysmal AF for decades, whereas other patients with the sa...

متن کامل

Electropathological substrate of longstanding persistent atrial fibrillation in patients with structural heart disease: epicardial breakthrough.

BACKGROUND During persistent atrial fibrillation (AF), waves with a focal spread of activation are frequently observed. The origin of these waves and their relevance for the persistence of AF are unknown. METHODS AND RESULTS In 24 patients with longstanding persistent AF and structural heart disease, high-density mapping of the right and left atria was performed during cardiac surgery. In a r...

متن کامل

Percutaneous alternative to the Maze procedure for the treatment of persistent or long-standing persistent atrial fibrillation (aMAZE trial): Rationale and design.

BACKGROUND Pulmonary vein antrum isolation (PVI) as a treatment of paroxysmal atrial fibrillation (AF) is associated with a high rate of success; however, outcomes for treating persistent and long-standing persistent AF with PVI alone are substantially lower and often require multiple procedures to maintain long-term freedom from atrial arrhythmias. Foci and/or substrate outside the pulmonary v...

متن کامل

Surgical and concomitant epicardial-endocardial (hybrid) ablation of persistent and long-standing persistent atrial fibrillation.

Catheter ablation of atrial fibrillation (AF) has been shown to be effective for paroxysmal AF. However, for patients with persistent or longstanding persistent AF, the success rates for catheter ablation is low. The Cox-Maze procedure is the most effective non-pharmacological treatment of AF. However, due to the need for open-heart surgery and the morbidity associated with the surgical Cox-Maz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010