Bedside nuclear probe for detection and quantification of left to right intracardiac shunts.

نویسندگان

  • B A Gould
  • J Turner
  • D H Keeling
  • N J Ring
  • R R Cox
  • A J Marshall
چکیده

A cadmium telluride nuclear probe with an Elscint gamma camera was used to detect and measure left to right intracardiac shunts at the bedside in 34 patients. Fifteen also had right heart catheterisation and oximetric measurement of the shunt. For the nuclear technique 740 MBq (20 mCi) of technetium-99m pertechnetate was injected into the right antecubital vein and the pulmonary to systemic flow ratio (QP:QS) was measured by the gamma variate technique. Data were not obtained in four patients because the nuclear probe failed in three patients and one storage disc was corrupted. Data from the gamma camera were lost in another patient. When the size of the shunt measured by the nuclear probe was compared with that measured by the oximetric technique the mean difference (SD of mean difference) was 0.36 (SD 0.78) and when it was compared with the gamma camera it was 0.08 (SD 0.67). Analysis of scatter plots showed that the larger the shunt, the larger the discrepancy. Twenty four of 29 data sets showed complete agreement between the nuclear probe and gamma camera on the size of the shunt. Any differences were small. These data indicate that left to right intracardiac shunts may be measured accurately by a nuclear probe at the bedside in either the coronary care unit or outpatient department.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Krypton-85 in the Detection of Intracardiac Left-to-right Shunts.

ANUMBER of methods have been developed for detecting left-to-right shunts during cardiac catheterization of which the most frequently employed is determining the difference in oxygen saturations. This method has limited application in the presence of small shunts, however, since the minimal changes are often within the error of this method.' Therefore, other more sensitive technics have been em...

متن کامل

Noninvasive detection and quantification of left-to-right shunts in children using oxygen-15 labeled carbon dioxide.

A method for the detection and quantification of left-to-right intracardiac shunts is described which utilizes a single breath inhalation of oxygen-15 labeled carbon dioxide (C15O2). The inhaled gas rapidly crosses the alveolar membrane and the oxygen-15 label is exchanged through the carbonate cycle to form oxygen-15 labeled water within the pulmonary capillary blood. Pulmonary indicator clear...

متن کامل

Quantification of intracardiac shunts by gold-195m, a new radionuclide with a short half life.

Gold-195m, a radionuclide with a short half life (30.5 s) was used to quantify left to right intracardiac shunts. The results of this method were compared with those obtained with technetium-99m, a method that was validated against oximetry. In five patients the pulmonary to systemic flow ratio (greater than 3:1) obtained by both radionuclides indicated that the level of shunting was too high t...

متن کامل

Oximetric detection of intracardiac left-to-right shunts.

To assess prevailing guidelines for the oximetric detection of intracardiac left-to-right shunts, we examined the variability of right heart oxygen saturation step-ups in 1121 catheterisations in children with aortic and pulmonary stenosis, who were studied as part of the joint study of the natural history of congenital heart defects. It is estimated that in the absence of intracardiac shunting...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 59 4  شماره 

صفحات  -

تاریخ انتشار 1988