Single Photon 2 { D Imaging System Prototype forBiopsy Digital Mammography
نویسندگان
چکیده
We have developed a digital radiography system based on double sided mi-crostrip silicon crystals. The detector is 300 m thick, equipped with 320 channels for each side. The strip pitch is 100 m. The read{out system consists of a VLSI integrated analog circuit with low noise preampliication, pulse shaping, threshold discrimination. The two main issues of this Front End chip are low noise and good timing information. It has 64 channels which provide a digital pulse whenever one strip of the detector is hit. The channel number is then encoded by the digital chip which is directly bonded to the analog Front{End. This is accomplished on both sides independently. To reconstruct the spatial position an X-Y coincidence unit is used. The two signals produced along the two coordinates are time related by sampling the Front{ End outputs with a common clock signal. The two correlated signals are then presented to the coincidence unit at the same clock cycle. To accomplish the on{line image reconstruction the time unit recognizes these correlated signals as one real event and updates a related histogram. This system is suitable for X{Ray imaging, optimized for stereotaxic mam-mography in the 18 ? 22 keV photon energy range.
منابع مشابه
Characterization and Optimization of Silicon-strip Detectors for Mammography and Computed Tomography
The goal in medical x-ray imaging is to obtain the image quality required for a given detection task, while ensuring that the patient dose is kept as low as reasonably achievable. The two most common strategies for dose reduction are: optimizing incident x-ray beams and utilizing energy information of transmitted beams with new detector techniques (spectral imaging). In this thesis, dose optimi...
متن کاملDigital Mammography with a Photon Counting Detector in a Scanned Multislit Geometry
Mammography screening aims to reduce the number of breast cancer deaths by early detection of the disease, which is one of the leading causes of deaths for middle aged women in the western world. The risk from the x-ray radiation in mammography is relatively low but still a factor in the benefit-risk ratio of screening. The characterization and optimization of a digital mammography system is pr...
متن کاملComparison of contrast detail curves of full field digital with screen film breast phantom images.
In this investigation, we imaged a standard breast phantom and compared the contrast detail curves from a prototype full breast digital mammography system with the corresponding curves for a conventional, analog screen-film system. The full breast digital system exhibited superior contrast detail detectability. The results from this study will be used to plan future clinical evaluations compari...
متن کاملA Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.
AIM The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of brea...
متن کاملUltra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...