An automated method for magnesium determination in serum is described using conventional AutoAnalyser equipment. The method gives results comparable with those obtained by the flame photometer. The method may prove particularly useful with subnormal serum magnesium levels.
منابع مشابه
ESTIMATION OF POTASSIUM, CALCIUM, AND MAGNESIUM IN BLOOD AND MYOCARDIAL TISSUE, AND DIAGNOSTIC IMPORTANCE OF URINARY MAGNESIUM EXCRETION IN EXPERIMENTALLY-INDUCED MYOCARDIAL INJURY
The results obtained in the present investigations point to a definite correlation between the onset of myocardial injury, electrocardiographic changes and biochemical changes. Changes in the electrocardiogram and elevated serum levels were paralleled by an increased excretion of magnesium in urine as early as one hour. Serum calcium and serum potassium levels did not show any significant ...
متن کاملA Novel Method for Automated Estimation of Effective Parameters of Complex Auditory Brainstem Response: Adaptive Processing based on Correntropy Concept
Objectives: Automated Auditory Brainstem Responses (ABR) peak detection is a novel technique to facilitate the measurement of neural synchrony along the auditory pathway through the brainstem. Analyzing the location of the peaks in these signals and the time interval between them may be utilized either for analyzing the hearing process or detecting peripheral and central lesions in the human he...
متن کاملA colorimetric method for the estimation of serum magnesium.
I955 The author wishes to express his sincere appreciation to Dr R. E. Hungate for an introduction to the fascinating cattle protozoa and for many stimulating discussions during the course of the experiments. The investigation was supported in part by funds for biological and medical research by the State of Washington, initiative measure number 171. In clinical work, where general electrolyte ...
متن کاملEstimation of calcium and magnesium in serum and urine by atomic absorption spectrophotometry.
A method has been described for the estimation of calcium and magnesium in serum and urine using atomic absorption spectrophotometry. The precision and accuracy of the techniques have been determined and were found to be acceptable. THE RANGE OF VALUES FOR CALCIUM AND MAGNESIUM IN THE SERA OF NORMAL ADULTS WAS FOUND TO BE: serum calcium (corrected to a specific gravity of 1.026) 8.38-10.08 mg. ...
متن کاملSemi-automated micromethod for estimating the unsaturated iron-binding capacity of serum using radioactive iron.
A semi-automated micromethod for the determination of the unsaturated iron-binding capacity (UIBC) of serum using radioactive iron and magnesium carbonate as an adsorbing substance is presented. The method has the advantage of simplicity and speed. The determination of UIBC is carried out on 0.1 ml of serum in duplicate, using autodiluters, at the rate of up to 200 sera per day. The reproducibi...