Experimental evaluation of indoor magnetic distortion effects on gait analysis performed with wearable inertial sensors.

نویسندگان

  • E Palermo
  • S Rossi
  • F Patanè
  • P Cappa
چکیده

Magnetic inertial measurement unit systems (MIMU) offer the potential to perform joint kinematics evaluation as an alternative to optoelectronic systems (OS). Several studies have reported the effect of indoor magnetic field disturbances on the MIMU's heading output, even though the overall effect on the evaluation of lower limb joint kinematics is not yet fully explored. The aim of the study is to assess the influence of indoor magnetic field distortion on gait analysis trials conducted with a commercial MIMU system. A healthy adult performed gait analysis sessions both indoors and outdoors. Data collected indoors were post-processed with and without a heading correction methodology performed with OS at the start of the gait trial. The performance of the MIMU system is characterized in terms of indices, based on the mean value of lower limb joint angles and the associated ROM, quantifying the system repeatability. We find that the effects of magnetic field distortion, such as the one we experienced in our lab, were limited to the transverse plane of each joint and to the frontal plane of the ankle. Sagittal plane values, instead, showed sufficient repeatability moving from outdoors to indoors. Our findings provide indications to clinicians on MIMU performance in the measurement of lower limb kinematics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Performances of Two Wearable Systems for Gait Analysis: A Pilot Study

Introduction: Wearable sensor systems to perform human motion analysis are receiving increasing attention in different application fields. Among wearable sensors, inertial sensors have promising features. However, before they can be employed routinely in clinical applications, it is important to evaluate their reliability. Gait analysis was performed on one male volunteer: data were simultaneou...

متن کامل

A Wearable Gait Analysis System using Inertial Sensors Part II - Evaluation in a Clinical Setting

The gold standard for gait analysis, in-lab 3D motion capture, is not routinely used for clinical assessment due to limitations in availability, cost and required training. Inexpensive alternatives to quantitative gait analysis are needed to increase the its adoption. Inertial sensors such as accelerometers and gyroscopes are promising tools for the development of wearable gait analysis (WGA) s...

متن کامل

Gait Partitioning Methods: A Systematic Review

In the last years, gait phase partitioning has come to be a challenging research topic due to its impact on several applications related to gait technologies. A variety of sensors can be used to feed algorithms for gait phase partitioning, mainly classifiable as wearable or non-wearable. Among wearable sensors, footswitches or foot pressure insoles are generally considered as the gold standard;...

متن کامل

Quantifying Variation in Gait Features from Wearable Inertial Sensors Using Mixed Effects Models

The emerging technology of wearable inertial sensors has shown its advantages in collecting continuous longitudinal gait data outside laboratories. This freedom also presents challenges in collecting high-fidelity gait data. In the free-living environment, without constant supervision from researchers, sensor-based gait features are susceptible to variation from confounding factors such as gait...

متن کامل

Wearable sensors for gait analysis Comparison between a MIMUs system and a gold standard electromechanical system

Systems based on inertial sensors are increasingly used in motion analysis due to their low cost, portability and wearability. However, since accuracy is crucial in clinical gait analysis, it is important to assess it in new systems. The aim of this study is to compare the performances of a magnetic and inertial sensors system (MIMUs) to a gold standard, the electromechanical system STEP32. Res...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physiological measurement

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 2014