Left ventricular volume measurement in mice by conductance catheter: evaluation and optimization of calibration.
نویسندگان
چکیده
The conductance catheter (CC) allows thorough evaluation of cardiac function because it simultaneously provides measurements of pressure and volume. Calibration of the volume signal remains challenging. With different calibration techniques, in vivo left ventricular volumes (V(CC)) were measured in mice (n = 52) with a Millar CC (SPR-839) and compared with MRI-derived volumes (V(MRI)). Significant correlations between V(CC) and V(MRI) [end-diastolic volume (EDV): R(2) = 0.85, P < 0.01; end-systolic volume (ESV): R(2) = 0.88, P < 0.01] were found when injection of hypertonic saline in the pulmonary artery was used to calibrate for parallel conductance and volume conversion was done by individual cylinder calibration. However, a significant underestimation was observed [EDV = -17.3 microl (-22.7 to -11.9 microl); ESV = -8.8 microl (-12.5 to -5.1 microl)]. Intravenous injection of the hypertonic saline bolus was inferior to injection into the pulmonary artery as a calibration method. Calibration with an independent measurement of stroke volume decreased the agreement with V(MRI). Correction for an increase in blood conductivity during the in vivo experiments improved estimation of EDV. The dual-frequency method for estimation of parallel conductance failed to produce V(CC) that correlated with V(MRI). We conclude that selection of the calibration procedure for the CC has significant implications for the accuracy and precision of volume estimation and pressure-volume loop-derived variables like myocardial contractility. Although V(CC) may be underestimated compared with MRI, optimized calibration techniques enable reliable volume estimation with the CC in mice.
منابع مشابه
Calibrating volume measurements made using the dual-field conductance catheter
The conductance catheter technique allows realtime measurements of ventricular volume based on changes in the electrical conductance of blood within the ventricular cavity. Conductance volume measurements are corrected with a calibration coefficient, α, in order to improve accuracy. However, conductance volume measurements are also affected by parallel conductance, which may confound calibratio...
متن کاملAssessment of right ventricular contractile state with the conductance catheter technique in the pig.
OBJECTIVE Since the conductance catheter method has facilitated evaluation of left ventricular contractile state in both laboratory and clinical studies, the aim of this study was to determine whether the technique is similarly useful for the right ventricle. METHODS A series of right ventricular pressure-volume loops was obtained in seven open chest pigs during transient vena caval occlusion...
متن کاملLABORATORY INVESTIGATION VENTRICULAR PERFORMANCE Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts
We evaluated the accuracy of the recently reported technique of estimating intraventricular volume by measurement of intracavitary electrical conductance in six isolated, ejecting, canine left ventricles. Left ventricular volumes were measured directly by a previously validated servosystem that employed an electroconductive balloon placed in the left ventricular cavity. The volume measured cont...
متن کاملDevelopment of a multifrequency conductance catheter-based system to determine LV function in mice.
Transgenic mice offer a valuable way to relate gene products to phenotype, but the ability to assess the cardiovascular phenotype with pressure-volume analysis has lagged. Conductance measurement offers a method to generate an instantaneous left ventricular (LV) volume signal in the mouse but has been limited by the volume signal being a combination of blood and LV muscle. We hypothesized that ...
متن کاملDynamic Correction for Parallel Conductance , GP , and 1 Gain Factor , α , in Invasive Murine Left Ventricular 2 Volume Measurements
The conductance catheter technique could be improved by determining instantaneous parallel 40 conductance (GP) which is known to be time-varying, and by including a time-varying calibration factor in 41 Baan’s equation (α(t)). We have recently proposed solutions to the problems of both time-varying GP and time42 varying α, which we term “admittance” and “Wei’s equation”, respectively. We valida...