Piezoelectric line detector array for photoacoustic tomography
نویسندگان
چکیده
Photoacoustic tomography relies on a dense coverage of the surface surrounding the imaged object with ultrasound sensors in order to enable an accurate reconstruction. A curved arrangement of integrating line sensors is proposed that is able to acquire data for a linear projection image of the absorbed energy density distribution in the object. Upon rotation of the object relative to the array, three-dimensional (3D) images can be obtained. The proposed design is based on the cost-effective piezoelectric polymer film technology with 64 line shaped sensors arranged on a half-cylindrical surface. It is combined with an optical parametric oscillator for the near infrared as a source for laser pulses. Image reconstruction from recorded signals consists of two-dimensional (2D) back projection followed by an inverse Radon transform. The tomograph exhibits a spatial resolution on the order of 200 to 250 μm. In a phantom experiment, the steps from acquisition of a single, 2D projection image to a full 3D image are demonstrated. Finally, in vivo projection images of a human finger are shown, revealing the near real-time imaging capability of the device in 2D.
منابع مشابه
Piezoelectric annular array for large depth of field photoacoustic imaging
A piezoelectric detection system consisting of an annular array is investigated for large depth of field photoacoustic imaging. In comparison to a single ring detection system, X-shaped imaging artifacts are suppressed. Sensitivity and image resolution studies are performed in simulations and in experiments and compared to a simulated spherical detector. In experiment an eight ring detection sy...
متن کاملIn Vivo Photoacoustic Imaging of Blood Vessels Using an Extreme-Narrow Aperture Sensor
We applied photoacoustics for noninvasive two-dimensional imaging of blood vessels in vivo, using near infrared light. This study was undertaken to develop photoacoustic tomography of tissue for the detection of embedded blood vessels using a newly developed piezoelectric double ring detector, featuring an extremely narrow aperture.
متن کاملPhotoacoustic tomography with a limited-aperture planar sensor and a reverberant cavity
Biomedical photoacoustic tomography (PAT) is a soft-tissue imaging modality which combines the high spatial resolution of ultrasound (US) with the contrast and spectroscopic opportunities afforded by imaging optical absorption. Planar US arrays composed of piezoelectric or optical detector elements with small element sizes and fast acquisition times are readily available, making them an attract...
متن کاملFiber-optic annular detector array for large depth of field photoacoustic macroscopy
We report on a novel imaging system for large depth of field photoacoustic scanning macroscopy. Instead of commonly used piezoelectric transducers, fiber-optic based ultrasound detection is applied. The optical fibers are shaped into rings and mainly receive ultrasonic signals stemming from the ring symmetry axes. Four concentric fiber-optic rings with varying diameters are used in order to inc...
متن کاملIn situ monitoring of electrochromic systems by piezoelectric detector photoacoustic spectroscopy of electrodes
Analytical Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 In situ monitoring of electrochromic systems by piezoelectric detector photoacoustic spectroscopy of electrodes Richard E. Malpas, and Allen J. Bard Anal. Chem., 1980, 52 (1), 109-112• DOI: 10.1021/ac50051a026 • Publication Date (Web): 01 May 2002 Downloaded from http://pubs.acs....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2017