MRI of the Gastrointestinal Tract 2 at High - Field Strength

نویسندگان

  • Aart J. Nederveen
  • Sonia I. Gonçalves
چکیده

High-fi eld imaging of the GI tract at 3 T can be very attractive in terms of signal to noise ratio (SNR) when compared with 1.5 T imaging. However, several issues need to be addressed and a direct transition of sequences used at 1.5–3 T is not possible. The main constraints in 3 T imaging are related to changes in tissue T1 and T2 relaxation parameters, susceptibility artifacts, changes in effi ciency of contrast agents, chemical shift artifacts, B1-inhomogeneity artifacts, specifi c absorption rate (SAR) limitations, and steady-state free precession (SSFP) banding artifacts. In general, a careful adjustment of sequence parameters is needed to avoid these artifacts. The use of parallel imaging techniques is more benefi cial at 3 T when compared with 1.5 T because by reducing scan time SAR problems often present at 3 T can be avoided. For reducing B1-inhomogeneity, hardware adjustments are needed. Banding artifacts generated in SSFP-sequences pose a severe limitation to the clinical use of these sequences. Though methods exist to overcome this problem, a satisfactory solution has not been proposed so far.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه یافته های سونوگرافیک و MRI در ناهنجاری های جنینی

Background and purpose: Ultra sonography is the method of choice in pre-natal diagnosis of fetal anomalies however, sonography has limitations in oligohydramnios, maternal obesity and complex fetal anomalies. MRI, is a method with high contrast resolution, large FOV for fetus, placenta and uterine, along with multiplanar images. The aim of our study is to compare the sonographic and MRI findi...

متن کامل

Identification of Helicobacter spp. in gastrointestinal tract, pancreas and hepatobiliary system of stray cats

The aim of the present study was to determine the presence of Helicobacter species in different parts of gastrointestinal tract, hepatobiliary system and pancreas of stray cats. Six different sites at the level of genus, gastric (H. heilmannii and H. felis) and enterohepatic species of Helicobacter were investigated in six cats using species-specific primers by polymerase chain reaction (PCR). ...

متن کامل

Prevalence of Gastrointestinal Tract Lesions in Patients with Iron-Deficiency Anemia

Background: the Iron deficiency anemia (IDA) is a common cause of referral to medical departments. Chronic gastrointestinal (GI) blood loss is important cause of IDA and also an alarming sign of serious underlying disease. The information concerning ideal evaluation of the gastrointestinal tract in patients with the IDA is scant. We designed a prospective study to determine the frequency of GI ...

متن کامل

Functional MRI in the rat at 9.4 T and 16.4 T

Introduction Functional MRI (fMRI) in animals at high magnetic fields keeps expanding our knowledge about the basics of thinking and the fMRIsignal itself. Yet, until the signal to noise ratio in MRI depends linearly on the magnetic field strength and calls for even stronger magnets for the detection of even smaller anatomical details, the relation between the functional MR-response and field s...

متن کامل

Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017