Noninvasive vascular function measurement in the community: cross-sectional relations and comparison of methods.
نویسندگان
چکیده
BACKGROUND Several methods of noninvasive vascular function testing have been suggested for cardiovascular risk screening in the community. A direct comparison of the different methods and their relation to classical cardiovascular risk factors in a large cohort is missing. METHODS AND RESULTS In 5000 individuals (mean age, 55.5 ± 10.9 years; age range, 35 to 74 years; women, 49.2%) of the population-based Gutenberg Heart Study, we performed simultaneous measurement of flow-mediated dilation (FMD) and peripheral arterial volume pulse determined by infrared photo (reflection index) and pneumatic plethysmography (PAT) and explored their associations. All function measures were recorded at baseline and after reactive hyperemia induced by 5-minute brachial artery occlusion. Correlations between different measures of vascular function were statistically significant but moderate. The strongest association for hyperemic response variables was observed for PAT ratio and FMD (Spearman r = 0.17; age- and sex-adjusted partial correlation, 0.068). Classical risk factors explained between 15.8% (baseline reflection index) and 58.4% (brachial artery diameter) of the baseline values but only accounted for 3.2% (reflection index), 15.4% (FMD), and 13.9% (PAT ratio) of the variability of reflective hyperemic response. Regression models varied in their relations to classical risk factors for the individual vascular function measures. Consistently associated with different vascular function methods were age, sex, body mass index, and indicators of hypertension. Peripheral tonometry also showed a relation to fasting glucose concentrations. CONCLUSIONS Noninvasive measures of conduit artery and peripheral arterial function are modestly correlated, differ in their relation to classical cardiovascular risk factors, and may thus reflect different pathologies.
منابع مشابه
Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملA Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates
Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...
متن کاملبررسی ارتباط مقاومت شرایین ریوی (PVR) و اندکسهای عملکرد بطنی
Abstract Background: Pulmonary vascular resistance (PVR) index is an important hemodynamic variable in determining the severity of cardiopulmonary diseases. This study was done to define the relationship of echocardiographic parameters of ventricular function with PVR. Methods: Mean PVR of 40 patients with cardiac disease was compared with the left ventricle diastolic function indices (LVEF...
متن کاملبررسی حجم و سطح مقطع بینی در جمعیت بالغین نرمال ایرانی توسط
Background & Aim: Objective assessment of nasal airway is helpful in understanding nasal breathing function. Acoustic rhinometry is one of the most commonly used objective measurements of nasal airway. This test has the ability to measure cross-sectional areas of the nose in different distances and volume and also determines the site of minimal cross-sectional area. These variables are diff...
متن کاملComparison of noninvasive prenatal testing of cell‐free DNA in maternal blood and amniocentesis for evaluation of aneuploidy
Background: The aim of this study was to compare noninvasive prenatal testing (NIPT) of cell‐free DNA in maternal blood and amniocentesis in the diagnosis of aneuploidy. This study was designed to evaluate sensitivity, specificity, accuracy, positive predictive value and negative predictive value of NIPT for detection of aneuploidies compared gold standard test of amniocentesis. Materials and m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular imaging
دوره 4 4 شماره
صفحات -
تاریخ انتشار 2011