Correction: evaluation of the Menarini-Arkray HA 8140 hemoglobin A1c analyzer.
نویسندگان
چکیده
To the Editor: John et al. (1) have evaluated the performance of the Menarini-Arkray HbA1c analyzer and have shown correlations of results on patient samples with the Bio-Rad Variant analyzer, an in-house HPLC method, a latex particle immunoassay, and an affinity chromatography method. The y 5 x lines in Fig. 2, b and d, do not appear to be in the correct position, probably because the x and y axes are numbered differently.
منابع مشابه
HbA 1 c : will the HbA 1 c auto - analyzer HA - 8160 ( Menarini Diagnostics ) imply a substantial improvement compared to the HA - 8140 ?
The Menarini HA-8160 HbA1c auto-analyzer has proven to be highly reliable, highly reproducible, technically simple to use, and appears a substantial improvement compared to the HA-8140. Physician-endocrinologists were informed about the new HbA1c analyzer HA-8160 and its analytical performance characteristics. In addition, issues that had to be considered in the clinical decision making process...
متن کاملNon-separation assay for glycohemoglobin.
The determination of glycohemoglobin [HbA1c, HbA1, or total glycohemoglobin (GHb)] has become an established procedure in the management of diabetes mellitus. Here, we describe the development of a simple, fluorescence, non-separation assay for the percentage of GHb (%GHb). The fluorescence of an eosin-boronic acid derivative when it was mixed with hemolysates of unwashed erythrocytes was quenc...
متن کاملEvaluation of Bio-Rad D-100 HbA1c analyzer against Tosoh G8 and Menarini HA-8180V
OBJECTIVES To evaluate the Bio-Rad D-100®, an HPLC analyzer for glycated hemoglobin (HbA1c) determination, and to compare its performance with the Menarini HA-8180V® and Sysmex G8®. METHODS Method comparison was performed according to Clinical and Laboratory Standards Institute (CLSI) EP9-A2 guidelines. We selected 100 samples from the routine laboratory workload and analyzed them in duplicat...
متن کاملInfluence of Iron Deficiency Anemia on Hemoglobin A1C Levels in Diabetic Individuals with Controlled Plasma Glucose Level
Introduction: Hemoglobin A1C (HbA1c) reflects patient’s glycemic status over the previous 3 months. Previous studies have reported that iron deficiency may elevate A1C concentrations, independent of glycemia. This study is aimed to analyze the effect of iron deficiency anemia on HbA1c levels in diabetic population having plasma glucose levels in control. Methods: Totally, 120 diabetic, iron-def...
متن کاملCapillarys 3 Octa®: Analytical Performance Assessment for HbA1c Quantification
Objective: Determination of HbA1c level is a precious indicator for therapeutic follow-up of patients with type 1 or type 2 diabetes. Our study aimed to evaluate the analytical characteristics of Capillarys 3 Octa® HbA1c measurement by capillary electrophoresis. Materials and Methods: Our study involved 265 venous whole blood specimens repeatability, intermediate fidelity, accuracy, linearity,...