Application of new data processing method for the photodiode array detector in the drug substance analysis.

نویسندگان

  • Łukasz Jedynak
  • Maria Puchalska
  • Joanna Zagrodzka
  • Wojciech Łuniewskij
  • Łukasz Kaczmarek
چکیده

While analyzing active pharmaceutical ingredients (APIs) it is necessary to determine both the assay of the drug substance itself and the content of impurities in a drug substance. The ideal situation is when both assay of drug substance and content of related substances can be determined simultaneously (1). However, as the impurities must be determined at relatively low levels, it is often impossible to select such analytical conditions, which allow to determine both the API assay and the content of impurities in one chromatographic run. Drug substance concentration in a method for the determination of its purity is often outside the linear range of the applied detector and an additional analytical procedure for the drug substance assay must be developed (2, 3). An Intelligent Dynamic Range Extension Calculator (i-DReC) is a new data processing method for the photodiode array detector, available in the LabSolutions software by Shimadzu. It allows to extend the linear range of chromatographic method by shifting the chromatographic profile to the wavelength where the target signal is not saturated. The peak area of the acquired chromatogram is corrected by the factor of the absorption ratio between the original target wavelength and the wavelength used by the i-DReC function. The iDReC is applied automatically when the intensity of the target peak exceeds the user-defined threshold value (4, 5). Temozolomide (3,4-dihydro-3-methyl-4oxoimidazo-[5,1-d]-as-tetrazine-8-carboxamide; TZ) is an oral alkylating drug used for the treatment of primary brain tumors (6, 7). The temozolomide signal is saturated in the method for the determination of temozolomide related substances used for the assessment of the chemical purity of temozolomide samples manufactured by Pharmaceutical Research Institute (PRI), which imposed the necessity of using separate methods for the temozolomide API assay and purity determination (2). The aim of the study was to apply the i-DReC data analysis function of the LabSolutions software to the determination of temozolomide assay using a method for the chemical purity determination. It was possible in spite of the temozolomide signal being saturated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Manipulation 3D Imaging System by using Photodiode Grid

Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...

متن کامل

Determination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study

Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...

متن کامل

Determination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study

Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...

متن کامل

Analysis of New Laser Warning Technologies to Propose a New Optical Subsystem

In this paper, after a brief overview on laser warning system (LWS), a new structure for an optical array that is used in its optical subsystem is introduced. According to the laser threats’ wavelengths (0.5 – 1.6 µm) and our desirable field of view (FOV), we used 6 lenses for gathering the incident radiation and then optimized the optical array. Lenses’ radius, their se...

متن کامل

Application of statistical techniques and artificial neural network to estimate force from sEMG signals

This paper presents an application of design of experiments techniques to determine the optimized parameters of artificial neural network (ANN), which are used to estimate force from Electromyogram (sEMG) signals. The accuracy of ANN model is highly dependent on the network parameters settings. There are plenty of algorithms that are used to obtain the optimal ANN setting. However, to the best ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta poloniae pharmaceutica

دوره 71 6  شماره 

صفحات  -

تاریخ انتشار 2014