Congruency of scapula locking plates: implications for implant design.

نویسندگان

  • Andrew Y Park
  • James G DiStefano
  • Thuc-Quyen Nguyen
  • Jenni M Buckley
  • William H Montgomery
  • Chris D Grimsrud
چکیده

We conducted a study to evaluate the congruency of fit of current scapular plate designs. Three-dimensional image-processing and -analysis software, and computed tomography scans of 12 cadaveric scapulae were used to generate 3 measurements: mean distance from plate to bone, maximum distance, and percentage of plate surface within 2 mm of bone. These measurements were used to quantify congruency. The scapular spine plate had the most congruent fit in all 3 measured variables. The lateral border and glenoid plates performed statistically as well as the scapular spine plate in at least 1 of the measured variables. The medial border plate had the least optimal measurements in all 3 variables. With locking-plate technology used in a wide variety of anatomical locations, the locking scapula plate system can allow for a fixed-angle construct in this region. Our study results showed that the scapular spine, glenoid, and lateral border plates are adequate in terms of congruency. However, design improvements may be necessary for the medial border plate. In addition, we describe a novel method for quantifying hardware congruency, a method that can be applied to any anatomical location.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Custom-made locked plating for acetabular fracture: a pilot study in 24 consecutive cases.

Clinical implementation of site-specific locking plates for acetabular fracture remains untested. Custom-made locking plates were manufactured using computer-aided design and computer-aided manufacture techniques for acetabular fractures to test this procedure. The 3-dimensional images constructed from computed tomography data of pelvises in patients with acetabular fractures were used for preo...

متن کامل

Removal of locking plates: new implant, new challenges and new solutions

Removal of locking plates in many ways poses novel challenges compared to conventional plates. None of the techniques described for the removal of locking plates are adequate for all situations. We report our experience of 27 patients from whom a total of 33 locking plates were removed. We also describe a novel technique for the removal of locking plates which in our experience could be used in...

متن کامل

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

متن کامل

Proximal Femur Locking Plate for Sub-Trochanteric Femur Fractures: Factors Associated with Failure

INTRODUCTION Proximal femur locking compression plates (PF-LCP) have gained popularity since their inception due to superior biomechanical stability and durability but clinical experience has shown conflicting results including implant failure. OBJECTIVE To study the incidence of implant failure in patients with sub-trochanteric fractures managed with proximal femoral locking compression plat...

متن کامل

Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.

OBJECTIVES Locked plating constructs may be too stiff to reliably promote secondary bone healing. This study used a novel imaging technique to quantify periosteal callus formation of distal femur fractures stabilized with locking plates. It investigated the effects of cortex-to-plate distance, bridging span, and implant material on periosteal callus formation. DESIGN Retrospective cohort stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of orthopedics

دوره 41 4  شماره 

صفحات  -

تاریخ انتشار 2012