Symmetrical Short Circuit Parameter Differences of Double Fed Induction Generator and Synchronous Generator Based Wind Turbine

نویسندگان

  • Muhammad Shahzad Nazir
  • Qinghua Wu
  • Mengshi Li
  • Luliang Zhang
چکیده

Considering the importance of perturbations during short circuit (SC) in power conversion devices, this study designed to find out the efficacy of symmetrical short circuit (SSC) of the synchronous generator (SG) and doubly fed induction generators (DFIG). Both wind power systems were separately built (Park’s model) and simulated. Simulation results showed that the DFIG is more efficient, fault tolerant, and proficient systems as compared to the SG based on the transient time, steady state, maximum current, and voltage dip values. This study can extend to design protection schemes, more accurate, stable and optimal proficient wind power conversion devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Different Turbine-generator Shaft Models on the Subsynchronous Resonance Phenomenon in the Double Cage Induction Generator Based Wind Farm

This paper focuses on the turbine-generator shaft models of double-cage Induction Generator (IG) based wind farm and its influence on the sub-synchronous resonance phenomenon. For this purpose, six different shaft models as 6-mass, 4-mass, 3-mass I, 3-mass II, 2-mass and 1-mass models are considered for double-cage IG wind-turbine. By using the linear modal analysis method, the effects of the d...

متن کامل

Sliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition

This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...

متن کامل

Large Disturbance Stability Analysis of Wind Turbine Implemented with DFIG

As one of the most promising Distributed Generation (DG) sources, wind power technology has been widely developed in recent years. Doubly fed induction generator (DFIG) is currently employed as one of the most common topologies for wind turbine generators (WTGs). This generator operates as a synchronous/asynchronous hybrid generators. Therefore, it is necessary to power engineers find understan...

متن کامل

Improving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller

Using the FACTS controllers, such as static synchronous compensator (STATCOM), as it provides continuous reactive power, in the grid including wind turbine (WT) equipped with doubly fed induction generator, for improving voltage profile (under normal circumstances) and providing a transition ability from inductor generator transition state has been proposed. In this paper, in order to contr...

متن کامل

Improving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller

Using the FACTS controllers, such as static synchronous compensator (STATCOM), as it provides continuous reactive power, in the grid including wind turbine (WT) equipped with doubly fed induction generator, for improving voltage profile (under normal circumstances) and providing a transition ability from inductor generator transition state has been proposed. In this paper, in order to contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017