Design and Validation of a Method to Determine the Position of the Fovea by Using the Nerve-Head to Fovea Distance of the Fellow Eye
نویسندگان
چکیده
PURPOSE To measure the nerve-head to fovea distance (NFD) on fundus photographs in fellow eyes, and to compare the NFD between fellow eyes. METHODS Diabetic patients without retinopathy, (n = 183) who were screened by fundus photography at the University Medical Center Groningen, the Netherlands from January 1(st) 2005 until January 1(st) 2006 were included. The NFD was measured in left and right eyes both from the center and from the rim of the nerve-head. To determine inter- and intra-observer agreement, repeated measurements by one observer (n = 3) were performed on all photographs and by two observers on 60 photographs (30 paired eyes). The effect of age, gender, and refractive error on NFD was analysed. RESULTS The correlation of NFDs between the left and the right eye was 0.958 when measured from the center of the nerve head (mean difference 0.0078 mm. ±SD 0.079 (95% limits of agreement -0.147-0.163)) and 0.963 when measured from the rim (mean difference 0.0056±SD 0.073 (95% limits of agreement -0.137-0.149)). Using the NFD between fellow eyes interchangeably, resulted in a standard error of 0.153 mm. Intra- and inter-observer variability was small. We found a significant effect of age (center of the nerve-head (P = 0.006) and rim of the nerve head (P = 0.003)) and refractive error (center of nerve-head (P<0.001) and rim of nerve head (P<0.001)) on NFD. CONCLUSIONS The NFD in one eye provides a confident, reproducible, and valid method to address the position of the fovea in the fellow eye. We recommend using the NFD measured from the center of the nerve-head since the standard error by this method was smallest. Age and refractive error have an effect on NFD.
منابع مشابه
Solar Retinopathy Following Methamphetamine Abuse
Purpose: To report a case of solar retinopathy following methamphetamine (MA) abuse. Case report: A 37-years-old man was visited with sudden painless loss of vision in both eyes. He was addicted to methamphetamine for three years. He used MA at the day of admission. Excessive sun gazing (4 hours) took place due to using hallucinations secondary to the MA. Visual acuity was 15/400 Snellen chart ...
متن کاملMorphine delays fovea development in the eyes of Wistar rat embryos possible involvement of corticosterone
Abstract* Introduction: Visual system have been considered as among important sensory system in animals’ life span and their survival is closely related to normal visual system functioning. Since in previous studies it have been revealed that morphine consumption during pregnancy could lead to defect and delay in nervous system development in the embryos, in the present study, changes induc...
متن کاملEvaluation of Normal Choroidal Thickness in Rasht Using SD-OCT EDI Imaging
Purpose: To measure choroidal thickness in normal subjects, using optical coherent tomography (OCT) in Rasht. Methods: Normal subjects older than 20 years, living in Rasht, were selected through systematic random sampling by using the city telephone directory. The subjects underwent comprehensive eye examinations for inclusion in the study. Then, choroidal thickness was measured in both eyes by...
متن کاملThree Dimensional Ultrasonography of the Eye and Measurement of Optical Nerve Sheet Diameter in Dog
Objective- To determine the possibility of three-dimensional ultrasonography (3DUS) and measurement of optical nerve sheet by this method. Design- Descriptive study. Animals- 10 mixed normal dogs (5males, 5 females), age 1-1.5 year, and weighting 15±5 kg Procedure- 3D ultrasounds of the eyes were evaluated and the normal optical nerves in 3DUS images were measured using Volouson 730 pro....
متن کاملDesigning, validation, and reliability assessment of software to acquire kinematics parameters of motion by image processing
Motion analysis systems are useful and effective equipment in biomechanics research. Unfortunately these systems are available for few researchers because these are expensive equipment. The aim of this study was to design and validation of a practical and inexpensive software, to determine the exact markers position in space and compute the kinematic of movement. In designing the software, the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013