Automated Detection and Quantification of Circadian Eye Blinks Using a Contact Lens Sensor.
نویسندگان
چکیده
PURPOSE To detect and quantify eye blinks during 24-hour intraocular pressure (IOP) monitoring with a contact lens sensor (CLS). METHODS A total of 249 recordings of 24-hour IOP patterns from 202 participants using a CLS were included. Software was developed to automatically detect eye blinks, and wake and sleep periods. The blink detection method was based on detection of CLS signal peaks greater than a threshold proportional to the signal amplitude. Three methods for automated detection of the sleep and wake periods were evaluated. These relied on blink detection and subsequent comparison of the local signal amplitude with a threshold proportional to the mean signal amplitude. These methods were compared to manual sleep/wake verification. In a pilot, simultaneous video recording of 10 subjects was performed to compare the software to observer-measured blink rates. RESULTS Mean (SD) age of participants was 57.4 ± 16.5 years (males, 49.5%). There was excellent agreement between software-detected number of blinks and visually measured blinks for both observers (intraclass correlation coefficient [ICC], 0.97 for observer 1; ICC, 0.98 for observer 2). The CLS measured a mean blink frequency of 29.8 ± 15.4 blinks/min, a blink duration of 0.26 ± 0.21 seconds and an interblink interval of 1.91 ± 2.03 seconds. The best method for identifying sleep periods had an accuracy of 95.2 ± 0.5%. CONCLUSIONS Automated analysis of CLS 24-hour IOP recordings can accurately quantify eye blinks, and identify sleep and wake periods. TRANSLATIONAL RELEVANCE This study sheds new light on the potential importance of eye blinks in glaucoma and may contribute to improved understanding of circadian IOP characteristics.
منابع مشابه
Assessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain
Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...
متن کاملA clinical decision support system for contact lens evaluation
Background: Contact lenses are transparent, thin plastic disks that cover the surface of the cornea. Appropriate lens prescription should be performed properly by an expert to provide better visual acuity and reduce side effects. The lens administration is a multi-stage, complex and time-consuming process involving many considerations. The purpose of this study was to develop a decision support...
متن کاملEffects of transient blur and VDT screen luminance changes on eyeblink rate.
PURPOSE A study was designed to evaluate the efficacy of three different strategies aiming at increasing spontaneous eyeblink rate (SEBR) during computer use. METHODS A total of 12 subjects (5 female) with a mean age of 28.7 years were instructed to read a text presented on a computer display terminal during 15min. Four reading sessions (reference and three "blinking events" [BE]) were progra...
متن کاملElectrophoresis of tear proteins as a new diagnostic tool for two high risk groups for dry eye: computer users and contact lens wearers
RATIONALE Dry eye is the most prevalent condition seen by the ophthalmologist, in particular in elderly. The identification of new common risk factors (computer use and contact lens wear) extends the disease among the young people. The early diagnosis of dry eye is essential, but difficult, because the biochemical changes in tear film usually occur before any detectable signs. Due its advantage...
متن کاملA Promising Enhanced Polymer Modified Voltammetric Sensor for the Quantification of Catechol and Phloroglucinol
In the present paper, poly(Tyrosine) modified graphene paste electrode (PTMGPE) was fabricated by utilizing an electropolymerization technique. Deposition of polymer film at bare graphene paste electrode (BGPE) was characterized by field emission scanning electron microscopy (FE-SEM). The PTMGPE was applied for Voltammetric detection of catechol (CC) and its quantification in phosphate buffer s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Translational vision science & technology
دوره 4 1 شماره
صفحات -
تاریخ انتشار 2015