Reducing between scanner differences in multi-center PET studies
نویسندگان
چکیده
This work is part of the multi-center Alzheimer's Disease Neuroimaging Initiative (ADNI), a large multi-site study of dementia, including patients having mild cognitive impairment (MCI), probable Alzheimer's disease (AD), as well as healthy elderly controls. A major portion of ADNI involves the use of [(18)F]-fluorodeoxyglucose (FDG) with positron emission tomography (PET). The objective of this paper is the reduction of inter-scanner differences in the FDG-PET scans obtained from the 50 participating PET centers having fifteen different scanner models. In spite of a standardized imaging protocol, systematic inter-scanner variability in PET images from various sites is observed primarily due to differences in scanner resolution, reconstruction techniques, and different implementations of scatter and attenuation corrections. Two correction steps were developed by comparison of 3-D Hoffman brain phantom scans with the 'gold standard' digital 3-D Hoffman brain phantom: i) high frequency correction; where a smoothing kernel for each scanner model was estimated to smooth all images to a common resolution and ii) low frequency correction; where smooth affine correction factors were obtained to reduce the attenuation and scatter correction errors. For the phantom data, the high frequency correction reduced the variability by 20%-50% and the low frequency correction further reduced the differences by another 20%-25%. Correction factors obtained from phantom studies were applied to 95 scans from normal control subjects obtained from the participating sites. The high frequency correction reduced differences similar to the phantom studies. However, the low frequency correction did not further reduce differences; hence further refinement of the procedure is necessary.
منابع مشابه
Validation and evaluation of a GATE model for MAMMI PET scanner
Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard. Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...
متن کاملPerformance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE
Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...
متن کاملInterpreting scan data acquired from multiple scanners: A study with Alzheimer's disease
Large, multi-site studies utilizing MRI-derived measures from multiple scanners present an opportunity to advance research by pooling data. On the other hand, it remains unclear whether or not the potential confound introduced by different scanners and upgrades will devalue the integrity of any results. Although there are studies of scanner differences for the purpose of calibration and quality...
متن کاملComparison of 6 PET scanners, a simulation study [Persian]
Introduction: Due to the large number of PET systems available in the market, it is not very easy to decide about the scanner of choice. Conducting a research in order to compare all different PET scanners is very time consuming and expensive and practically impossible. However, such comparison may be conducted using PET simulators. In this study, the performance of 6 different PET scanne...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...