The birth of nuclear medicine instrumentation: Blumgart and Yens, 1925.
نویسنده
چکیده
In 1925, Hermann Blumgart performed the first diagnostic procedure using radioactive indicators on humans; this first is well recognized. Less well recognized is the fact that Blumgart and his coworker Otto C. Yens, then a medical student, developed the first instrumentation used in a diagnostic procedure involving radioactive indicators. The instrumentation, a modified Wilson cloud chamber, turned out to be the detector most suitable for their purpose. Blumgart also showed remarkable foresight in outlining the requirements both for a satisfactory indicator (tracer) and for a satisfactory detector--requirements that still hold true today. The Blumgart-Yens modified cloud chamber was the birth of nuclear medicine instrumentation.
منابع مشابه
Fleming-Harrington Redistribution Wash-in Washout (FHRWW): The Platinum Standard for Nuclear Cardiology
The introduction of the Heisenberg Uncertainty principle and Nuclear Cardiology occurred simultaneously in 1925-1927. Thirty years later the Anger gamma camera would allow for a more sophisticated radioactive isotope counting to determine the presence or absence of disease. When employed with technetium-99m isotopes, ischemic heart disease can be inferred by differences in visual appearance of ...
متن کاملNuclear Medicine in the Philippines: A Glance at the Past, a Gaze at the Present, and a Glimpse of the Future
While the introduction of radioactive tracers in the study of metabolic pathways has been well-documented in clinical thyroidology as early as 1924, the widespread utilization in other clinical specialties has been hampered by slow developments in radiation-detecting devices and in the production of appropriate radiopharmaceuticals, in addition tothe morbid fear of radiation. In the Philippines...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملAssessment of Nuclear Moisture Density Gauges at a Secondary Standard Dosimetry Laboratory in Ghana during December 2015–December 2017
Introduction: Nuclear moisture density gauges are widely used in construction industry in different countries across the world, including Ghana, on a large scale. Like all irradiating devices, the nuclear gauges should be subjected to radiation safety assessment based on radiation protection and safety principles. Regarding this, the objective of this research was to i...
متن کاملA Report on IAEA/RCA C-7RAS 004-061/6 Training Course in Chiba, Japan in 2014
The C7-RAS 6/061-004 training course by the International Atomic Energy Agency/Regional Cooperative Agreement (IAEA/RCA) was held in Chiba in 2014. The syllabus, pre- and post-course evaluations, and survey questionnaire results were assembled in this course. The post-course evaluation, including 32 questions similar to the pre-course evaluation, was performed right after the end of the final...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 44 8 شماره
صفحات -
تاریخ انتشار 2003