Ceramic-on-ceramic total hip arthroplasty in patients younger than 20 years.
نویسندگان
چکیده
Total hip arthroplasty (THA) in the adolescent patient has historically shown relatively poor survivorship. This study reports the results of THA in young patients using contemporary ceramic bearings. Twenty-four THAs were performed using ceramic bearing surfaces in patients 20 years old or younger (mean, 16.4; range, 12-20). Average follow-up was 52 months (range, 25-123 months). The survival rate was 96%, with 1 revision for a loose acetabular component. Other complications included a peroneal nerve palsy that resolved and 2 dislocations in 1 patient. Postoperatively, the Modified Harris Hip Score mean was 93.4 (range, 66-100). This study shows promising results at short-term to midterm follow-up in very young patients who undergo THA using ceramic-on-ceramic components.
منابع مشابه
Ceramic-on-ceramic bearings total hip arthroplasty in young patients
BACKGROUND The results of ceramic-on-ceramic (CoC) total hip arthroplasty (THA) in younger patients were not univocal. This study aims to evaluate the results of CoC bearing THA in patients younger than 50 years. METHODS A total of 90 younger patients performed CoC THAs during March 2003 and May 2008 were included in this study. Hip function and activity were evaluated with Harris hip score a...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملAlumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.
BACKGROUND Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contempor...
متن کاملCeramic-on-ceramic total hip arthroplasty: incidence and risk factors of bearing surface-related noises in 125 patients.
The ceramic-on-ceramic bearing surface has high wear resistance and good biocompatibility in total hip arthroplasty (THA). However, the postoperative noise problem has been an important issue. The purpose of this retrospective study was to determine the incidence and risk factors of bearing surface-related noises in patients with third-generation ceramic-on-ceramic THAs. One hundred twenty-five...
متن کاملSevere metallosis leading to femoral head perforation.
This article describes a case of severe metallosis in a 67-year-old woman who initially underwent primary total hip arthroplasty with a ceramic-on-ceramic articular bearing. This was subsequently revised to a metal-on-polyethylene articulation due to ceramic liner fracture. She presented with severe hip pain and a pelvic mass. Infective workup was negative. Perforation of the cobalt-chrome femo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of arthroplasty
دوره 27 2 شماره
صفحات -
تاریخ انتشار 2012