An 8-channel add-on RF shimming system for whole-body 7 Tesla MRI including real-time SAR monitoring

نویسندگان

  • A. K. Bitz
  • I. Brote
  • S. Orzada
  • O. Kraff
  • S. Maderwald
  • H. H. Quick
  • P. Yazdanbakhsh
  • K. Solbach
  • A. Bahr
  • T. Bolz
  • K. Wicklow
  • F. Schmitt
  • M. E. Ladd
چکیده

A. K. Bitz, I. Brote, S. Orzada, O. Kraff, S. Maderwald, H. H. Quick, P. Yazdanbakhsh, K. Solbach, A. Bahr, T. Bolz, K. Wicklow, F. Schmitt, and M. E. Ladd Erwin L. Hahn Institute for MRI, Essen, Germany, Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany, University Duisburg-Essen, Duisburg, Germany, IMST GmbH, Kamp-Lintfort, Germany, Siemens Healthcare, Erlangen, Germany

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Average SAR Constrained Local RF Shimming

Introduction Achieving given homogeneity and SAR constraints in RF shimming process is an important problem in high field MRI. There are different studies in the literature which dealt with the optimization of these parameters by using non-convex optimization techniques. In a previous work whole body SAR constrained RF shimming problem was solved in order to achieve whole slice transmit homogen...

متن کامل

Comparison of Whole Body Transmit Coil Configurations for RF Shimming at 3T

Introduction Whole body MRI at 3T may be impeded by B1 transmit field inhomogeneities caused by the dielectric shortening of the RF wavelength [1]. RF shimming techniques based on parallel transmission [2,3] can strongly improve the image quality in clinical whole body applications [4]. In this context, it is an important question, how the RF shimming performance depends on the chosen coil topo...

متن کامل

SAR and Temperature Evaluations for B1 Shimming at 7 tesla

Introduction In high field MRI, the increased interactions between the electromagnetic waves and the biological tissues may give rise to heat and thermal hazards. This is clearly apparent for multi-transmit array applications where the electromagnetic fields are heavily manipulated in the subject to be imaged. In this work we provide complete 3D predictions of the B1 + fields, MRI images, energ...

متن کامل

Towards Patient-specific SAR Calculation for Parallel Transmission Systems

Introduction The safety assessment via the specific absorption rate (SAR) is a prerequisite for in vivo MRI experiments. In parallel transmission, such an assessment is non-trivial, since the local SAR distribution does not only depend on the individual patient anatomy, but also on the multi-channel excitation. In general, patient safety can be achieved by carrying out simulation-based SAR calc...

متن کامل

Parallel Excitation in Ultrahigh Field Human MR Imaging and Multi-Channel Transmit System.

Parallel excitation [1,2] with a multi-element Radio Frequency (RF) transceiver array [3-9] as a contemporary methodology has been advocated for human MR imaging at ultrahigh magnetic fields (7 Tesla and above). In ultrahigh field MRI, the required high operating frequency and thus shortened wavelength of radio frequency waves creates a complex wave behavior and increased phase variation of RF ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008