Construction and calibration of detectors for high-resolution metabolic breast cancer imaging
نویسندگان
چکیده
Each of two detectors used in our Positron Emission Mammography (PEM) system consists of four 36 mm x 36 mm x 20 mm bismuth germanate (BGO) crystal detector blocks coupled to a crossed-wire anode position-sensitive photomultiplier tube (PS-PMT). To facilitate high spatial-resolution imaging, the crystal blocks have been finely pixelated using a diamond saw. In each detector, 36 x 36 1.9 mm x 1.9 mm crystal elements are coupled directly to the PMT window and, on the opposite face of the blocks, 35 x 35 elements are offset by 1.0 mm along both the .Yand y-axis of the PS-PMT. As part of a system calibration routine, a novel method for crystal element identification has been developed. This algorithm successfully identifies 59 x 49 crystal elements on each detector face. These results are used to generate a Look-Up-Table &UT) that is accessed during image formation for the effective correction of spatial distortion inherent in the detectors. Crystal identification also facilitates the capability for accurate energy discrimination, since the detector gain is considered on an element-by-element basis by accessing an energy LUT. Employing a third LUT, which contains the relative efficiencies of individual crystal elements results in improvement in image uniformity from 50% to 13%.
منابع مشابه
New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...
متن کاملImproving 3-D Imaging Breast Cancer Diagnosis Systems Using a New Method for Placement of Near-Infrared Sources and Detectors
The objective of this research was to improve 3-D imaging system by near-infrared light emission in breast tissue to achieve a more accurate diagnosis of tumor. The results of repeated experiments in this research have shown that with this imaging system, a more accurate diagnosis of abnormal area depends on the location of the sources and detectors. Therefore, an optimal location model has bee...
متن کاملValidation and evaluation of a GATE model for MAMMI PET scanner
Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard. Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...
متن کاملBreast cancer imaging: a new role of Tc-99m sestamibi prone scintimammography for diagnosisof breast cancer
Mammography remians the procedure of choice in screening asymptomatic women for breast cancer. However, in patients with symptoms, other types of imaging play an important role in the detection of malignancies. The high cost and lack of availability of PET and MRI largely precludes the use in this patient population. TI-201 is nbt the imaging agent of choice because of its wash-out and redistri...
متن کاملVerification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors
Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general, the uncertainty in the dose delivered should fall within ± 5% of the...