Dynamic Simulation Model of a Vapor Compression Domestic Refrigerator Running With R134a
نویسندگان
چکیده
منابع مشابه
Performance Comparison of Domestic Refrigerator using HFC134a and HFC134a/HC Refrigerant Mixture
An experimental performance comparison study on domestic refrigerator system was conducted and compared with HFC134a and M09 (HFC134a and HC blend (containing 55.2%HC600a and 44.8%HC290 by weight)) mixture refrigerant. The domestic refrigerator system was initially designed to operate with HFC134a.Experimental results showed that the refrigeration capacity of the refrigerant M09 mixture system ...
متن کاملThermodynamic Optimization of Household Refrigerator Using Propane –Butane as Mixed Refrigerant
A household refrigerator designed to work with R-134a was used as an investigation unit to assess the prospect of using mixed refrigerants. The recital of the refrigerator using mixed refrigerant was investigated and compared with the performance of refrigerator when R-134a was used as refrigerant. The effect of condenser temperature and evaporator temperature on COP, refrigerating effect was i...
متن کاملDynamical modeling and thermo-economic optimization of a cold room assisted vapor-compression refrigeration cycle
A cold room assisted vapor-compression refrigeration cycle is dynamically modeled in a year and optimized. Total annual cost (TACO) and coefficient of performance (COP) are selected as two objective functions. Both cold room and refrigeration cycle parameters are considered as design variables. Moreover, three working fluids included R22, R134a and R407c are examined. The optimum Pareto front r...
متن کاملDynamic Behaviour of a Vapor Compression Refrigerator: A Theoretical and Experimental Analysis
A THEORETICAL AND EXPERIMENTAL ANALYSIS Claudio Melo Rogerio Tadeu da Silva Ferreira Universidade Federal de Santa Catarina (UFSC) Departamento de Engenharia Mecanica Caixa Postal 476 88049 Florianopolis SC BRAZIL Roberto Horn Pereira cezar Otaviano Ribeiro Negrao Empresa Brasileira de compressores S/A (EMBRACO S /A) Rua Rui Barbosa, 1020 caixa Postal D-27 89.200 Joinville SC BRAZIL This work p...
متن کاملCost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant
This paper presents a cost-effective method to increase the COP and utility of a domestic refrigerator using R-134a refrigerant. A cabin was installed on the top of a domestic refrigerator with condenser coils of refrigerator serving as heating coils inside the cabin. Known quantity of water was heated by the condenser coils (due to convection currents) thereby increasing the overall COP of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014