Response to letter re: Carotid atherosclerotic plaques standardized uptake values: methodological issues on reproducibility and accuracy
نویسنده
چکیده
Correspondence/Findings To assess accuracy and precision of the positron emission tomography-computed tomography (PET-CT) carotid standardized uptake values (SUV) of 18F– fluorodeoxyglucose (18FDG) as an inflammatory biomarker for determining cerebrovascular diseases such as stroke, methodology and statistical issues should be taken into account. Otherwise, misleading messages will be the main outcome of such research. Briefly, confusing accuracy and precision will mainly produce misleading messages. I was interested to read the paper by Giannotti N and colleagues published in the Dec 2017 issue of EJNMMI Res [1]. Positron emission tomography-computed tomography (PET-CT) carotid standardized uptake values (SUV) of F–fluorodeoxyglucose (FDG) have been proposed as an inflammatory biomarker for determining cerebrovascular diseases such as stroke. Consideration of varying methodological approaches and software packages is critical to the calculation of accurate SUVs in cross-sectional and longitudinal patient studies. They aimed to investigate whether or not carotid atherosclerotic plaque SUVs are consistent and reproducible between software packages [1]. FDG-PET SUVs of carotids were taken in 101 patients using two different software packages [1]. Data from five to seven anatomical sites were measured. A total of ten regions of interest (ROI) were drawn on each site. Based on their results statistically significant differences in SUV measurements, between the two software packages, ranging from 9 to 21.8% were found depending on ROI location. In 79% (n = 23) of the ROI locations, the differences between the SUV measurements from each software package were found to be statistically significant. They highlighted the importance of standardizing all aspects of methodological approaches to ensure accuracy and reproducibility. However, reproducibility (precision, repeatability, reliability, or interchangeability) and accuracy (validity) are two completely different methodological issues [2–8]. The methodological approach and statistical estimates to assess these issues are completely different. For reliability purposes, our approach should be individual based. It means for continues variables, intraclass correlation coefficient (ICCC) absolute agreement single measure should be considered. 9 to 21% statistically significant differences in SUV measurements between the two software packages indicate that the authors did not applied this approach. They considered global average approach for reliability which is a common mistake and usually applied to assess accuracy of a test compared to a gold standard. It is crucial to know that a test can be accurate with no reliability and vice versa. Moreover, statistically significant should not be considered in reproducibility analysis because it dramatically depends on the sample size [2–8]. Finally, confusing Correspondence: [email protected] Safety Promotion and Injury Prevention Research Center, Shahid Beheshti University of Medical Sciences, Tehran, IR, Iran Department of Clinical Epidemiology, Shahid Beheshti University of Medical Sciences, Tehran, IR, Iran
منابع مشابه
Carotid atherosclerotic plaques standardised uptake values: software challenges and reproducibility
BACKGROUND Positron emission tomography-computed tomography (PET-CT) carotid standardised uptake values (SUV) of 18F-fluorodeoxyglucose (18FDG) have been proposed as an inflammatory biomarker for determining cerebrovascular diseases such as stroke. Consideration of varying methodological approaches and software packages is critical to the calculation of accurate SUVs in cross-sectional and long...
متن کامل64Cu-DOTATATE PET/MRI for Detection of Activated Macrophages in Carotid Atherosclerotic Plaques: Studies in Patients Undergoing Endarterectomy.
OBJECTIVE A feature of vulnerable atherosclerotic plaques of the carotid artery is high activity and abundance of lesion macrophages. There is consensus that this is of importance for plaque vulnerability, which may lead to clinical events, such as stroke and transient ischemic attack. We used positron emission tomography (PET) and the novel PET ligand [(64)Cu] [1,4,7,10-tetraazacyclododecane-N...
متن کامل(18)F-FDG imaging of human atherosclerotic carotid plaques reflects gene expression of the key hypoxia marker HIF-1α.
To investigate the association between gene expression of key molecular markers of hypoxia and inflammation in atherosclerotic carotid lesions with 2-deoxy-2-[(18)F]fluoro-D-glucose ((18)F-FDG) uptake as determined clinically by positron emission tomography (PET). Studies using PET have demonstrated (18)F-FDG-uptake in patients with confirmed plaques of the carotid artery. Inflammatory active o...
متن کامل18FDG PET and ultrasound echolucency in carotid artery plaques.
OBJECTIVES The objective was to evaluate inflammation in echolucent carotid artery plaques. BACKGROUND Ultrasound echolucency of carotid artery plaques has been proven to differentiate patients at high risk of stroke. On the other hand, positron emission tomography (PET) of plaques with the use of [(18)F]-fluorodeoxyglucose (FDG) identifies highly inflamed plaques, and the combination of mole...
متن کاملCommentary. Characterization of carotid artery plaques using real-time compound B-mode ultrasound.
BACKGROUND AND PURPOSE Real-time compound ultrasound imaging is a new technique for improving the image quality of B-mode scanning. We investigated the value of this method for the characterization of atherosclerotic plaques in the internal carotid artery. METHODS Thirty-two patients (22 men, 10 women; mean age, 75 years) with plaques of the internal carotid artery as identified by high-resol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2017