Validation With Positron Emission Tomography

نویسندگان

  • Bernard De Bruyne
  • Thierry Baudhuin
  • Jacques A. Melin
  • Walter J. Paulus
  • Guy R. Heyndrickx
چکیده

Background Experimental studies have shown that fractional flow reserve (defined as the ratio of maximal achievable flow in a stenotic area to normal maximal achievable flow) can be calculated from coronary pressure measurements only. The objectives of this study were to validate fractional flow reserve calculation in humans and to compare this information with that derived from quantitative coronary angiography. Methods and Results Twenty-two patients with an isolated, discrete proximal or mid left anterior descending coronary artery stenosis and normal left ventricular function were studied. Relative myocardial flow reserve, defined as the ratio of absolute myocardial perfusion during maximal vasodilation in the stenotic area to the absolute myocardial perfusion during maximal vasodilation (adenosine 140 jig. kg`. min` intravenously during 4 minutes) in the contralateral normally perfused area, was assessed by `50-labeled water and positron emission tomography (PET). Myocardial and coronary fractional flow reserve were calculated from mean aortic, distal coronary, and right atrial pressures recorded during maximal vasodilation. Distal coronary pressures were measured by an ultrathin, pressure-monitoring guide wire with minimal influence on the transstenotic pressure gradient. Minimal obstruction area, percent area stenosis, and calculated stenosis flow reserve were assessed by quantitative coronary angiography. There was no difference in heart rate, mean aortic pressure, or rate-pressure product during maximal vasodilation during PET and during catheterization. Percent area stenosis ranged from 40% to 94% (mean, 77±13%), myocardial fractional flow reserve from 0.36 to 0.98 (mean, 0.61±0.17), and relative flow reserve from 0.27 to 1.23 (mean, 0.60±0.26). A close correlation was found between relative flow reserve obtained by PET and both myocardial fractional flow reserve (r=.87) and coronary fractional flow reserve obtained by pressure recordings (r=.86). The correlations between relative flow reserve obtained by PET and stenosis measurements derived from quantitative coronary angiography were markedly weaker (minimal obstruction area, r=.66; percent area stenosis, r=-.70; and stenosis flow reserve, r=.68). Conclusions Fractional flow reserve derived from pressure measurements correlates more closely to relative flow reserve derived from PET than angiographic parameters. This validates in humans the use of fractional flow reserve as an index of the physiological consequences of a given coronary artery stenosis. (Circulation. 1994;89:1013-1022.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging

Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging  yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

An overview on Ga-68 radiopharmaceuticals for positron emission tomography applications

Gallium-68 a positron emitter radionuclide, with great impact on the nuclear medicine, has been widely used in positron emission tomography (PET) diagnosis of various malignancies in humans during more recent years especially in neuroendocrine tumors (NETs). The vast number of 68Ge/68Ga related generator productions, targeting molecule design (proteins, antibody fragments,...

متن کامل

The effect of fasting on Positron Emission Tomography (PET) imaging

As a nuclear approach, Positron Emission Tomography (PET) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. There are certain limitations to this technique such as normal tissue uptake. Therefore, it has been recommended that patients prepare before scanning. Fasting for a short while before PET imaging is an exampl...

متن کامل

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

متن کامل

Imaging Cellular Proliferation in Prostate Cancer with Positron Emission Tomography

Prostate cancer remains a major public health problem worldwide. Imaging plays an important role in the assessment of disease at all its clinical phases, including staging, restaging after definitive therapy, evaluation of therapy response, and prognostication. Positron emission tomography with a number of biologically targeted radiotracers has been demonstrated to have potential diagnostic and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005