Analysis of lidocaine on the COBAS INTEGRA.

نویسندگان

  • L Y Liu-Allison
  • R A Hui
  • K S Schwenzer
چکیده

A new fluorescence polarization (FP) immunoassay was developed for the COBAS INTEGRA to quantitate lidocaine in serum and sodium heparin derived plasma. The COBAS INTEGRA, a random and continuous access clinical analyzer, performs the new lidocaine assay at a throughput of 300 tests per hour. Comparison studies with the Abbott TDx Lidocaine assay yielded a correlation coefficient of 0.99 and a regression value of INTEGRA = -0.01 + 0.95 TDx, n = 69. The assay was found to be linear throughout the concentration range of 0 to 10 micrograms/ml using CASCO STANDARDS's DOCUMENT TDM 1 Linearity Test Set and the COBAS-FP TDM Calibration Verification Test Set. The new lidocaine assay exhibited good precision as determined by the National Committee for Clinical Laboratory Standards (NCCLS) protocol EP5-T2 with total percent coefficient of variation (%CV) values of less than 4 percent across the assay range. Interference was less than 10 percent for abnormal levels of total protein (2.1 to 10 g/dl), lipid (up to 2200 mg/dl triglyceride), hemoglobin (up to 10 g/dl), and icteric samples (up to 17.5 mg/dl bilirubin). Finally, the standard curve was stable for greater than 25 weeks which was attributable to the on-board reagent cooling and a unique cassette closure system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of the Roche Total Mycophenolic Acid® assay on the Cobas Integra 400®, Cobas 6000® and comparison to LC-MS/MS in liver transplant patients.

BACKGROUND Mycophenolic acid (MPA) is an immunosuppressant for which therapeutic drug monitoring (TDM) is performed for optimal prophylaxis and avoidance of toxicity in transplant patients. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is ideally suited for TDM of MPA. There have been several method comparisons of the Roche Total MPA assay, but none have been performed with respect ...

متن کامل

Evaluation of five new liquid stable applications on the Roche Cobas Integra.

In the present study the analytical performances of five new liquid applications on the Roche Cobas Integra were evaluated: urea and high density lipoprotein (HDL) cholesterol in serum and glucose, creatinine and inorganic phosphorus in urine. The analytical evaluation consisted of imprecision, linearity and method comparison performed against either the actual Cobas Integra granulate applicati...

متن کامل

Comparative evaluation of the My5-FU™ immunoassay and LC-MS/MS in monitoring the 5-fluorouracil plasma levels in cancer patients.

BACKGROUND Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring...

متن کامل

Effective Assessment of Diabetes Control Using Personal Glucometers (CONTOURLINK, Bayer, Germany; CALLA, Wellion, Austria; LINUS, Agamatrix, USA)

Aim of this trial was to assess (1) the accuracy and precision of electrochemistry-based glucometers CONTOURLINK, CALLA, and LINUS and (2) the diabetes control using Ambulatory Glycaemic Profiles (AGP) as markers of therapeutic effectiveness. Glucometers and COBAS INTEGRA 400 Plus analyzer were used by one laboratory professional to estimate P-glucose (PG) in 112 out-patients. There were 112 se...

متن کامل

Association of Selected Biochemical Markers and Body Mass Index in Women with Endocrine Disorders

Obesity is frequent attendant phenomenon of patients with endocrinological disease. Between BMI and endocrinological diseases is close correlation. In thesis we focused on the allocation of hormone concentration – PTH and TSH, CHOL a mineral element Ca in a blood serum. The examined group was formed by 100 respondents (women) aged 36 – 83 years, who were divided into two groups – control group ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 27 2  شماره 

صفحات  -

تاریخ انتشار 1997