The Swiss IMRT dosimetry intercomparison using a thorax phantom.

نویسندگان

  • H Schiefer
  • A Fogliata
  • G Nicolini
  • L Cozzi
  • W W Seelentag
  • E Born
  • F Hasenbalg
  • J Roth
  • B Schnekenburger
  • K Münch-Berndl
  • V Vallet
  • M Pachoud
  • B Reiner
  • G Dipasquale
  • B Krusche
  • M K Fix
چکیده

PURPOSE In 2008, a national intensity modulated radiation therapy (IMRT) dosimetry intercomparison was carried out for all 23 radiation oncology institutions in Switzerland. It was the aim to check the treatment chain focused on the planning, dose calculation, and irradiation process. METHODS A thorax phantom with inhomogeneities was used, in which thermoluminescence dosimeter (TLD) and ionization chamber measurements were performed. Additionally, absolute dosimetry of the applied beams has been checked. Altogether, 30 plan-measurement combinations have been used in the comparison study. The results have been grouped according to dose calculation algorithms, classified as "type a" or "type b," as proposed by Kntis et al. ["Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations," Phys. Med. Biol. 51, 5785-5807 (2006)]. RESULTS Absolute dosimetry check under standard conditions: The mean ratio between the dose derived from the single field measurement and the stated dose, calculated with the treatment planning system, was 1.007 +/- 0.010 for the ionization chamber and 1.002 +/- 0.014 (mean+/- standard deviation) for the TLD measurements. IMRT Plan Check: In the lung tissue of the planning target volume, a significantly better agreement between measurements (TLD, ionization chamber) and calculations is shown for type b algorithms than for type a (p <0.001). In regions outside the lungs, the absolute differences between TLD measured and stated dose values, relative to the prescribed dose, [(Dm-Ds)/Dprescribed], are 1.9 +/- 0.4% and 1.4 +/- 0.3%, respectively. These data show the same degree of accuracy between the two algorithm types if low-density medium is not present. CONCLUSIONS The results demonstrate that the performed intercomparison is feasible and confirm the calculation accuracies of type a and type b algorithms in a water equivalent and low-density environment. It is now planned to offer the intercomparison on a regular basis to all Swiss institutions using IMRT techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental evaluation of midline dose calculation methods in In vivo dosimetry using anatomic thorax phantom

Background: In vivo dosimetry is a method for estimation of overall error in the delivered dose to the patients at the end of radiotherapy process. In this research, two methods for target dose calculation were evaluated on midline and central axis of photon beams in in vivo dosimetry of thorax fields. Materials and Methods: Entrance and exit doses for anterior and lateral fields of thorax were...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

Acrylonitrile Butadiene Styrene (ABS) plastic‐based low cost tissue equivalent phantom for verification dosimetry in IMRT

A novel IMRT phantom was designed and fabricated using Acrylonitrile Butadiene Styrene (ABS) plastic. Physical properties of ABS plastic related to radiation interaction and dosimetry were compared with commonly available phantom materials for dose measurements in radiotherapy. The ABS IMRT phantom has provisions to hold various types of detectors such as ion chambers, radiographic/radiochromic...

متن کامل

Investigating the Feasibility of 3D Dosimetry in the RPC IMRT H&N Phantom.

An urgent requirement for 3D dosimetry has been recognized because of high failure rate (~25%) in RPC credentialing, which relies on point and 2D dose measurements. Comprehensive 3D dosimetry is likely to resolve more errors and improve IMRT quality assurance. This work presents an investigation of the feasibility of PRESAGE/optical-CT 3D dosimetry in the Radiologic Physics Center (RPC) IMRT H&...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 37 8  شماره 

صفحات  -

تاریخ انتشار 2010