Evaluation of subcutaneously-implanted glucose sensors for continuous glucose measurements in hyperglycemic pigs.

نویسندگان

  • Peter Helding Kvist
  • Mia Bielecki
  • Michael Gerstenberg
  • Charlotte Rossmeisl
  • Henrik Elvang Jensen
  • Bidda Rolin
  • Erik Hasselager
چکیده

BACKGROUND Subcutaneously-implanted glucose sensors for continuous glucose monitoring have the potential to replace serial blood glucose measurements. The objective of the present study was to test whether continuous glucose measurements could be obtained with glucose sensors implanted in the subcutis of pigs. Moreover, the in vivo biocompatibility of the sensors was evaluated since an inflammatory reaction may lead to drift in sensor-signaling. MATERIALS AND METHODS Two types of glucose sensor were implanted for 3 days in the subcutis of hyperglycemic pigs. The plasma glucose concentration was correlated to the sensor outputs, and tissue was sampled for histological evaluation. RESULTS There was a good correlation between the interstitial fluid and blood glucose levels. However, there was a statistical significantly difference in linearity from days 0 and 1 to day 2 (p<0.001) and variations in the sensitivity and background current of individual sensors were observed over time. The tissue reaction caused by the sensors was a mild focal subacute fibrinous dermatitis. CONCLUSION Continuous glucose measurement can be achieved by glucose sensors implanted in the subcutis of pigs. The observed drift in sensor signals over time may have been caused by heterophils, macrophages and/or fibrinogen at the tissue-sensor interface.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a novel continuous glucose measurement device in patients with diabetes mellitus across the glycemic range.

BACKGROUND This glucose clamp study assessed the performance of an electrochemical continuous glucose monitoring (CGM) system for monitoring levels of interstitial glucose. This novel system does not require use of a trocar or needle for sensor insertion. METHOD Continuous glucose monitoring sensors were inserted subcutaneously into the abdominal tissue of 14 adults with type 1 or type 2 diab...

متن کامل

Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes.

OBJECTIVE The capability of emerging glucose sensor technology to continuously monitor glucose levels may provide ways to achieve glycemic targets while reducing hypoglycemia. RESEARCH DESIGN AND METHODS A first-generation, long-term continuous glucose sensor (DexCom, San Diego, CA) was implanted subcutaneously in 15 patients with type 1 diabetes. Safety, efficacy, and potential benefits were...

متن کامل

Differential Metabolic Effects of Novel Cilostamide Analogs, Methyl Carbostiryl Derivatives, on Mouse and Hyperglycemic Rat

Objective(s) PDE3 has a functional role in insulin secretion and action. We investigated the metabolic effects of new synthetic PDE3 inhibitors (mc1, mc2, mc5 and mc6), on mice and hyperglycemic rat. Materials and Methods The test compound or solvent was injected subcutaneously to mice, for 7 days. On day 8, blood and liver samples were obtained. In hyperglycemic rat, 0.5 g/kg glucose with o...

متن کامل

Continuous Glucose Monitoring Sensors: Past, Present and Future Algorithmic Challenges

Continuous glucose monitoring (CGM) sensors are portable devices that allow measuring and visualizing the glucose concentration in real time almost continuously for several days and are provided with hypo/hyperglycemic alerts and glucose trend information. CGM sensors have revolutionized Type 1 diabetes (T1D) management, improving glucose control when used adjunctively to self-monitoring blood ...

متن کامل

Continuous monitoring of glucose in subcutaneous tissue using microfabricated differential affinity sensors.

OBJECTIVE We describe miniaturized differential glucose sensors based on affinity binding between glucose and a synthetic polymer. The sensors possess excellent resistance to environmental disturbances and can potentially allow wireless measurements of glucose concentrations within interstitial fluid in subcutaneous tissue for long-term, stable continuous glucose monitoring (CGM). METHODS The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • In vivo

دوره 20 2  شماره 

صفحات  -

تاریخ انتشار 2006