Patient-specific calibration for breast MRI: breast-coil insertable reference phantom

نویسندگان

  • M. Heisen
  • B. Peng
  • A. M. Wood
  • D. Mustafi
  • J. Buurman
  • G. M. Newstead
  • G. S. Karczmar
چکیده

Introduction: The routine use of a calibration phantom that fits easily into a breast coil could provide the basis for standardization and patient-specific calibration of breast MRI. Here, we use a phantom to correct the variable flip angles in a T1 measurement. This increases the accuracy of T1 and contrast media concentration measurements obtained with a clinically employed T1-weighted dynamic contrast-enhanced protocol. Methods: A unique phantom was designed, with a comfortable breast-coil insert mounted with color-coded circumferential and vertical tubes filled with distilled water solutions containing Gd-DTPA (0.0, 0.1, 0.2, 0.3, 0.4, 0.5 mM, Omniscan). The geometry of the phantom was adjusted so that multiple phantom compartments were present in many slices, irrespective of slice orientation. A healthy volunteer (no contrast media injected, University of Chicago Institutional Review Board approval) was scanned in a standard bilateral breast coil at 1.5 T with one breast placed in the phantom cup. Clinical T2-weighted (2D turbo spin echo, TR/TE = 5647/120 ms) and T1-weighted (fat-suppressed ultrafast gradient echo, flip angle (FA) = 12°, TR/TE = 12.6/3.7 ms) images were acquired. A variable flip angle protocol was used for T1 measurement (3D FSPGRE, nominal FA’s = 3, 5, 10, 15, 20, 30°, TR/TE = 5.0/1.5 ms, NA = 3). The clinical images were evaluated by an experienced breast radiologist to assess image quality in the presence of the phantom. In addition, the clinical T1-weighted image was used to measure phantom signal intensities as a function of T1. Based on theoretical T1 values in the phantom, the true flip angles were estimated and these values were used to calculate accurate T1’s for breast tissue. Results: The circumferential phantom compartments (vertical compartments are not visible in this projection; they are on the backside) and their appearance on the T2and T1-weighted MR images are displayed in the figure below. In the graph, the measured phantom signal intensities are plotted as a function of the theoretical T1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible Four Element Phased Array Coil for Supine Breast MRI

INTRODUCTION Dynamic contrast enhanced breast MRI shows a high sensitivity for breast cancer [1]. To avoid respiratory motion artifacts, breast MR images are currently acquired with the patient in a prone position. Supine unilateral breast MRI has several applications including scanning of patients with known claustrophobic sensations, as an aid to breastconserving surgeries and guidance of bre...

متن کامل

A study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy

Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...

متن کامل

MR Scanner Systems Should Be Adequately Characterized in Diffusion-MRI of the Breast

Breast imaging represents a relatively recent and promising field of application of quantitative diffusion-MRI techniques. In view of the importance of guaranteeing and assessing its reliability in clinical as well as research settings, the aim of this study was to specifically characterize how the main MR scanner system-related factors affect quantitative measurements in diffusion-MRI of the b...

متن کامل

X-ray properties of an anthropomorphic breast phantom for MRI and x-ray imaging.

The purpose of this study is to characterize the x-ray properties of a dual-modality, anthropomorphic breast phantom whose MRI properties have been previously evaluated. The goal of this phantom is to provide a platform for optimization and standardization of two- and three-dimensional x-ray and MRI breast imaging modalities for the purpose of lesion detection and discrimination. The phantom is...

متن کامل

A comparison of calibration data from full field digital mammography units for breast density measurements

BACKGROUND Breast density is a significant breast cancer risk factor measured from mammograms. The most appropriate method for measuring breast density for risk applications is still under investigation. Calibration standardizes mammograms to account for acquisition technique differences prior to making breast density measurements. We evaluated whether a calibration methodology developed for an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009