In vitro drug adsorption and plasma free hemoglobin levels associated with hollow fiber oxygenators in the extracorporeal life support (ECLS) circuit.
نویسندگان
چکیده
The purpose of this study was to identify the percentage of fentanyl or morphine sulfate lost from adhesion to either the polyvinylchloride (PVC) tubing or the surface of two different hollow fiber oxygenators used in current extracorporeal life support circuits and to identify any difference in the plasma free hemoglobin (PFH) levels generated when using these oxygenator and/or drug combinations. For each drug examined, six simple circuits were assembled; for each drug, two circuits contained tubing without an oxygenator (control), two circuits contained the Jostra Quadrox D (Maquet Cardiopulmonary, AG Hirrlingen, Germany), and two circuits contained the Terumo Baby Rx (Terumo Cardiovascular Systems Corp., Ann Arbor, MI). Fentanyl or morphine sulfate was added to yield initial circuit concentrations equal to 1430 ng/mL, respectively. Throughout the 6-hour in vitro testing, samples to evaluate the drug and PFH levels were drawn at various time intervals. Significance in this study is defined as p < .05. Fentanyl's initial adsorption seems to be 80% in circuits without oxygenators, 86% in the circuits containing the Quadrox D oxygenator, and 83% in the circuits with the Baby Rx oxygenator. Morphine sulfate seems to be initially adsorbed at a rate of 40% in all circuits and does not seem to be adsorbed by either of the tested oxygenators. The PFH levels were significantly (p < .05) elevated in the fentanyl circuits. The type of oxygenator does not seem to play a significant role in drug adsorption. During this in vitro study, the majority of both drugs were lost to the PVC tubing. The type of oxygenator did not seem to significantly affect PFH. However, fentanyl in any combination or alone was associated with increased PFH levels.
منابع مشابه
Modified surface coatings and their effect on drug adsorption within the extracorporeal life support circuit.
A recently completed study quantified the percent of fentanyl or morphine sulfate lost to uncoated polyvinylchloride (PVC) tubing or to one of two hollow fiber oxygenators within the extracorporeal life support (ECLS) circuit. The results demonstrated the majority of drug loss was due to adsorption by the PVC tubing. The purpose of this study was to determine if a tubing coating process affects...
متن کاملTrends and emerging technologies in extracorporeal life support: results of the 2006 ECLS survey.
Extracorporeal life support (ECLS) is a procedure used to support the failing heart and/or lungs via a heart lung machine. Over 145 institutions perform this practice in the United States with more than 24,000 ECLS cases recorded. While many articles are published each year on common perfusion practice, little information is shared on emerging technologies in ECLS and common practices among per...
متن کاملRetrospective analysis comparing hollow fiber and silicone membrane oxygenators for neonates on ECMO.
There is little information showing the use of microporous polypropylene hollow fiber oxygenators during extra-corporeal life support (ECLS). Recent surveys have shown increasing use of these hollow fibers amongst ECLS centers in the United States. We performed a retrospective analysis comparing the Terumo BabyRx hollow fiber oxygenator to the Medtronic 800 silicone membrane oxygenator on 14 ne...
متن کاملPlasma-free hemoglobin levels in advanced vs. conventional infant and pediatric extracorporeal life support circuits.
Extracorporeal life support (ECLS) is a reliable method to support pediatric patients with reversible cardiorespiratory failure associated with congenital heart disease, respiratory insufficiency, or after cardiac surgery. In 2010, our institution adopted an infant/pediatric extracorporeal membrane oxygenation (ECMO) circuit that contains a magnetically levitated centrifugal pump, polymethylpen...
متن کاملExtracorporeal life support in severe drug intoxication: a retrospective cohort study of seventeen cases
INTRODUCTION Cardiovascular failure is the leading cause of death in severe acute drug intoxication. In this setting, we report the feasibility, complications, and outcome of emergency extracorporeal life support (ECLS) in refractory shock or cardiac arrest following a drug overdose. METHODS This is a retrospective cohort study of 17 patients admitted over a 10-year period for prolonged cardi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of extra-corporeal technology
دوره 39 4 شماره
صفحات -
تاریخ انتشار 2007