Liquid chromatography-accurate radioisotope counting and microplate scintillation counter technologies in drug metabolism studies.
نویسندگان
چکیده
The present study involves an analysis of the performance of liquid chromatography (LC)-accurate radioisotope counting (ARC) and microplate scintillation counter (TopCount) technologies in drug metabolism studies. For the purpose of evaluating these systems, biological samples resulting from the metabolism of a radiolabeled [14C] compound, known as compound B, are analyzed using LC-ARC and TopCount under similar high-performance LC conditions. Counting efficiency is 83% for LC-ARC, 77% for TopCount, and linearity is R2 of 0.9998 versus 0.9984, respectively. The limit of detection for LC-ARC is 12 disintegrations per minute (dpm) with 1-min/fraction counting, yet for TopCount it is 8.7 dpm with 5-min/fraction counting. Under optimal conditions for each, the total run time of LC-ARC is approximately half that of TopCount. These results indicate that there is no significant difference between these two systems in terms of efficiency, linearity, and limit of detection. However, the LC-ARC system does not involve any manual operations, yet TopCount requires manual sample transfer and data import. This study shows that impressive progress has been made in the technology of radioisotope counting in drug metabolism using LC-ARC. This system enhances the resolution of radiochromatograms and is able to measure volatile metabolites that TopCount cannot detect at all. The ability to acquire mass spectra online is also a major advancement. The overall results suggest that the combination of LC-ARC with radioactivity detection and mass spectrometry has great potential as a powerful tool for radioisotope measurement in metabolite identification studies during drug discovery and development.
منابع مشابه
Determination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]
Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...
متن کاملCounting Non-Aqueous Samples in the TopCount® Microplate Scintillation and Luminescence
The microplate format has become a standard for many biological assays such as high throughput screening for drug discovery and radioimmunoassays. Productivity with these high volume procedures has been limited by the amount of sample handling required and low sample counting throughput. Now, however, microplate assays can be efficiently counted in microplates with the Packard TopCount Micropla...
متن کاملScintillation Proximity Assay on the TopCount Microplate Scintillation Counter
The TopCountTM Microplate Scintillation Counter quantitates radioisotopes by liquid scintillation counting in standard microplate formats. Assays that previously had to be transferred from microplates to vials or to non-standard formats for counting can now be quantitated directly in microplates. TopCount can count up to 12 samples simultaneously with performance comparable to that of discrete ...
متن کاملCounting Aqueous Samples with the TopCount Microplate Scintillation Counter
The TopCountTM Microplate Scintillation Counter quantitates radioisotopes by liquid scintillation counting in standard microplate formats. Assays that previously had to be transferred from microplates to vials or to non-standard formats for counting can now be quantitated directly in microplates. TopCount can count up to 12 samples simultaneously with performance comparable to that of discrete ...
متن کاملCerenkov Counting Performance on the TopCount Microplate Scintillation and Luminescence Counter
The TopCount Microplate Scintillation and Luminescence Counter has been widely used in biopharmaceutical assays involving both radionuclide and luminescence measurement. A new feature allows the use of TopCount for measuring a high energy beta emitter such as P by Cerenkov counting, a well-known measurement technique that has the main advantage of not requiring the addition of scintillation coc...