Cost-Effectiveness of Percutaneous Closure of the Left Atrial Appendage in Atrial Fibrillation Based on Results From PROTECT AF Versus PREVAIL.
نویسندگان
چکیده
BACKGROUND Randomized trials of left atrial appendage (LAA) closure with the Watchman device have shown varying results, and its cost effectiveness compared with anticoagulation has not been evaluated using all available contemporary trial data. METHODS AND RESULTS We used a Markov decision model to estimate lifetime quality-adjusted survival, costs, and cost effectiveness of LAA closure with Watchman, compared directly with warfarin and indirectly with dabigatran, using data from the long-term (mean 3.8 year) follow-up of Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation (PROTECT AF) and Prospective Randomized Evaluation of the Watchman LAA Closure Device in Patients With Atrial Fibrillation (PREVAIL) randomized trials. Using data from PROTECT AF, the incremental cost-effectiveness ratios compared with warfarin and dabigatran were $20 486 and $23 422 per quality-adjusted life year, respectively. Using data from PREVAIL, LAA closure was dominated by warfarin and dabigatran, meaning that it was less effective (8.44, 8.54, and 8.59 quality-adjusted life years, respectively) and more costly. At a willingness-to-pay threshold of $50 000 per quality-adjusted life year, LAA closure was cost effective 90% and 9% of the time under PROTECT AF and PREVAIL assumptions, respectively. These results were sensitive to the rates of ischemic stroke and intracranial hemorrhage for LAA closure and medical anticoagulation. CONCLUSIONS Using data from the PROTECT AF trial, LAA closure with the Watchman device was cost effective; using PREVAIL trial data, Watchman was more costly and less effective than warfarin and dabigatran. PROTECT AF enrolled more patients and has substantially longer follow-up time, allowing greater statistical certainty with the cost-effectiveness results. However, longer-term trial results and postmarketing surveillance of major adverse events will be vital to determining the value of the Watchman in clinical practice.
منابع مشابه
Left Atrial Appendage Ligation and Exclusion Technology in the Incubator.
Stroke is the most feared complication of atrial fibrillation (AF). Targeting the left atrial appendage (LAA) mechanically is attractive as a means to simultaneously reduce stroke risk, the need for anticoagulation, and hemorrhagic complications in patients with non-valvular AF. The results of the PROTECT-AF and PREVAIL randomized clinical trials support this approach as a viable therapeutic al...
متن کاملA Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کاملLeft Atrial Appendage Closure as an Alternative to Warfarin for Stroke Prevention in Atrial Fibrillation: A Patient-Level Meta-Analysis.
BACKGROUND The risk-benefit ratio of left atrial appendage closure (LAAC) versus systemic therapy (warfarin) for prevention of stroke, systemic embolism, and cardiovascular death in nonvalvular atrial fibrillation (NVAF) requires continued evaluation. OBJECTIVES This study sought to assess composite data regarding left atrial appendage closure (LAAC) in 2 randomized trials compared to warfari...
متن کاملResponse by Panikker et al to Letter Regarding Article, "Left Atrial Appendage Electrical Isolation and Concomitant Device Occlusion to Treat Persistent Atrial Fibrillation: A First-in-Human Safety, Feasibility, and Efficacy Study".
Response by Panikker et al to Letter Regarding Article, “Left Atrial Appendage Electrical Isolation and Concomitant Device Occlusion to Treat Persistent Atrial Fibrillation: A First-inHuman Safety, Feasibility, and Efficacy Study” In Response: We thank Vroomen et al for their letter detailing the benefits of hybrid atrial fibrillation ablation, involving thoracoscopic epicardial ablation combin...
متن کاملCost effectiveness of left atrial appendage closure with the Watchman device for atrial fibrillation patients with absolute contraindications to warfarin
AIMS Atrial fibrillation (AF) patients with contraindications to oral anticoagulation have had few options for stroke prevention. Recently, a novel oral anticoagulant, apixaban, and percutaneous left atrial appendage closure (LAAC) have emerged as safe and effective therapies for stroke risk reduction in these patients. This analysis assessed the cost effectiveness of LAAC with the Watchman dev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 9 6 شماره
صفحات -
تاریخ انتشار 2016