Long-term clinical and angiographic follow-up after coronary stent placement in native coronary arteries.
نویسندگان
چکیده
BACKGROUND Although coronary stents have been proved effective in reducing clinical cardiac events for up to 3 to 5 years, longer term clinical and angiographic outcomes have not yet been fully clarified. METHODS AND RESULTS To evaluate longer term (7 to 11 years) outcome, clinical and angiographic follow-up information was analyzed in 405 patients with successful stenting in native coronary arteries. Primary or secondary stabilization, which was defined as freedom from death, coronary artery bypass grafting, and target lesion-percutaneous coronary intervention (TL-PCI) during the 14 months after the initial procedure or after the last TL-PCI, was achieved in 373 patients (92%) overall. Only 7 patients (1.7%) underwent TL-PCI more than twice. After the initial 14-month period, freedom from TL-PCI reached a plateau at 84.9% to 80.7% over 1 to 8 years. However, quantitative angiographic analysis in 179 lesions revealed a triphasic luminal response characterized by an early restenosis phase until 6 months, an intermediate-term regression phase from 6 months to 3 years, and a late renarrowing phase beyond 4 years. Minimal luminal diameter in 131 patients with complete serial data were 2.62+/-0.4 mm immediately after stenting, 2.0+/-0.49 mm at 6 months, 2.19+/-0.49 mm at 3 years, and 1.85+/-0.56 mm beyond 4 years (P<0.0001). CONCLUSIONS The efficacy and safety of coronary stenting seemed to be clinically sustained at 7 to 11 years of follow-up. However, late luminal renarrowing beyond 4 years was common, which demonstrates the need for further follow-up.
منابع مشابه
Safety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملRestenosis After Placement of Palmaz - Schatz Stents in Native Coronary Arteries
Background. Several metallic intracoronary stents are currently undergoing preliminary evaluation to ascertain potential benefit as means to reduce the 30-40% incidence of restenosis after balloon angioplasty. Methods and Results. To determine the incidence and correlates of restenosis after placement of Palmaz-Schatz stents in native coronary arteries in the first group of patients selected fo...
متن کاملRestenosis after placement of Palmaz-Schatz stents in native coronary arteries. Initial results of a multicenter experience.
BACKGROUND Several metallic intracoronary stents are currently undergoing preliminary evaluation to ascertain potential benefit as means to reduce the 30-40% incidence of restenosis after balloon angioplasty. METHODS AND RESULTS To determine the incidence and correlates of restenosis after placement of Palmaz-Schatz stents in native coronary arteries in the first group of patients selected fo...
متن کامل'Fused-Gold' vs. 'Bare' stainless steel NIRflex stents of the same geometric design in diseased native coronary arteries. Long-term results from the NIR TOP Study.
OBJECTIVES We evaluated the long-term clinical and angiographic results of 'fused-gold' (NIRFlex Royal) and 'bare' (NIRFlex) stainless steel stents in patients undergoing percutaneous coronary intervention (PCI). BACKGROUND Recent studies have shown high clinical and angiographic restenosis rates following the intracoronary implantation of 'gold-coated' stainless steel stents. The new 'fused-...
متن کاملAngiographic follow-up of traumatic carotid cavernous fistulas treated with endovascular stent graft placement.
BACKGROUND AND PURPOSE Endovascular treatment (EVT) of carotid cavernous fistulas (CCFs) is based on various techniques, mainly those using detachable balloons. Coronary covered stent grafts have been sporadically used in the intracranial arteries and only 2 traumatic CCFs have been reported in the literature; moreover, there is poor information about the long-term follow-up. We present 8 cases...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 105 25 شماره
صفحات -
تاریخ انتشار 2002